Series 6.0 Software (0510-1079-B) - User Guide 97
Event Types
Escort Expired
This alarm occurs when the selected amount of time required for a patient to be escorted has expired and the
transmitter, in the Escort mode, has not been moved from or has not yet been returned to the protected area.
To respond to an Escort Expired Alarm
1. Determine the location of the patient.
2. From the Client computer, click anywhere in the Escort Expired Alarm Message Box to access the
Event Information window.
3. Select one of the following event causes:
Patient Delayed—the patient was delayed and the Escort may need more time.
Failed to start—the Escort was never started.
Escort Completed—the patient was successfully escorted.
Te st —the system was being tested.
Other—opens a Clear Reason window, user must enter the cause in this window.
You cannot clear an event until you select the appropriate cause for the event.
4. If the patient has not yet been moved, perform the Escort function again.
5. If the patient has been escorted and is being returned to the monitored area:
a. Bring the patient back through the door; a Door Alarm will occur.
b. Follow the procedures for handling a Door Alarm (refer to “Door Alarm” on page 80).
c. Select Escort problem for the cause. of the Door Alarm.
Escort Complete
This alarm occurs when the Escort for a patient is complete. This dialog box only appears if the software has
been configured to confirm the escort.The Confirm Escort is configured in the Configuration, Global Settings
menu (refer to the Series 6.0 Software Administrator Guide).
Transfer to Expire
This alarm occurs when the time allowed for a patient to be transferred will expire in 15-minutes (if the
allotted time was configured for greater than 15-minutes) and the alarming band transmitter, in the Transfer
mode, has not been moved from one protected area to another.
To respond to a Transfer to Expire
1. Determine the location of the patient.
2. If the patient is secure and will not be transferred to a protected area soon, clear the Transfer to
Expire alarm and reset the duration time for the Transfer.
3. If the patient has not yet been moved, clear the Transfer to Expire alarm and cancel the Transfer.