Specifications
This section contains information on maximum power cable run lengths for installation of daisy-chained
Quick Response Premiere Wireless Routers/Gateways. It also provides specifications for the Quick
Response Premiere Wireless devices, including details about the specific requirements and certifications.
Power Cable Run Lengths
Number of Routers/Gateways
CPS
16/2AWG
CPS
18/2 AWG
8
390'
245'
7
450'
280'
6
525'
325'
5
630'
390'
4
785'
490'
3
1050'
650'
2
1575'
980'
1
3150'
1960'
FIGURE 4.1: Powered by CPS
Number of Routers/Gateways
12V @ 1.5A
18/2AWG
9.0V @ 200mA
22/2 AWG
7
140'
N/A
6
160'
N/A
5
200'
N/A
4
250'
N/A
3
330'
N/A
2
500'
N/A
1
1000'
125'