Step 5—Verify Software Operation
1. Test the software
a. At the Central Server, activate a Pendant transceiver by pressing the button. If the transceiver is
functioning properly, its green light will flash a series of times, indicating that it is sending a
signal.
b. If the software is responding, an Alarm event will be listed on the Event List at the Central Server.
c. Reset the transceiver by rapidly pressing the button six times. The green light will flash each time
the button is pressed. If the transceiver is reset properly, the green light will flash a series of times,
indicating that the Reset signal is being transmitted.
d. If the software is responding, a Reset event will be listed on the Event List at the Central Server.
2. Test the system for sufficient coverage
a. At a remote location in the facility, activate a Pendant transceiver by pressing the button. If the
transceiver is functioning properly, its green light will flash a series of times, indicating that it is
sending a signal.
If there is sufficient coverage by the Routers, an Alarm event will be listed on the Event List
at the Central Server.
If your facility is using a paging system in conjunction with your Quick Response Premiere
Wireless Call System, an Alarm message will be received by the pager.
b. Again at a remote location, reset the transceiver by rapidly pressing the button six times. The
green light will flash each time the button is pressed. If the transceiver is reset properly, the green
light will flash a series of times, indicating that the Reset signal is being transmitted.
If there is sufficient coverage by the Routers, a Reset event will be listed on the Event List
at the Central Server.
If your facility is using a paging system in conjunction with your Quick Response Premiere
Wireless Call System, a Reset message will be received by the pager.
c. Repeat these steps at several locations to ensure that the transceiver’s signal is received from all
areas.
Step-6—Monitor System for Device Faults
1. Let the system run overnight.
2. Verify there are no Device Faults within the 24 hours.