CHAPTER 1 Installing Hardware Components
Quick Response Premiere Wireless Call System Hardware Installation Guide Page 5 of 64
0510-1099-E
CHAPTER 1
Installing Hardware Components
Introduction
The basic components of the system consist of the Central Server, the Gateway, the Router and the transceiver
devices. The Central Server is a RF Technologies configured computer that runs the software. It contains the
database and provides communication with the devices in the system. The Computer Monitoring Station must
be permanently located at the central nurse’s station.
Depending on your configuration, the system can include several Client computers. The Client computers allow
the user to perform such functions as admitting, discharging, and clearing alarms. Each Client computer
includes a touchscreen monitor that displays alarms as they occur on a floor plan of the facility.
Although this manual describes the many various devices that can be included, the minimum system
configuration must consist of no less than the following devices:
One patient station (Pull Cord or Nurse Call Jack and Cord or Pendant)
Dome Light
QR Premiere Gateway
QR Premiere Router
32 Zone Relay Output Assembly
Computer Monitoring Station
This chapter provides detailed information about setting up the Central Server and installing hardware
components to use in conjunction with the software. It also provides an Installation Checklist to assist with the
installation process.
WARNING: When installing product, you must follow standard accepted
safety practices such as wearing safety glasses.
WARNING: Before cutting openings or drilling holes through walls, you
must verify that you will not strike any wiring or plumbing.