User Manual

Chapter 2: Installing Transceiver Devices
32 9600 Series Wireless Call System (0510-1078-D) - Hardware Installation Guide
Nurse Call
A Nurse Call is affixed near the bed of the patient. An Assistance
Required alarm event is reported in the Event List when a patient pushes
the button on the Nurse Call cord set. The Nurse Call is supervised; a
routine signal is sent from the transceiver and if the signal is not received
by the system, a Device Fault event is generated in the Event List at the
computer.
Additionally, a Nurse Call Cord Set Tamper alarm is initiated when the Nurse Call cord set is removed from
the Nurse Call. The Nurse Call is powered by a replaceable 3V battery within the Universal enclosure.
To wire the Universal transceiver to the Nurse Call
The 9600 Series Universal transceiver is wired directly to the Nurse Call terminal block using the 22 AWG
wire.
1. Terminate the wires from the Universal transmitter to the Nurse Call per the diagram below.
*The wire labeling is on the underside of the Universal transceivers circuit board.
2. Use your fingers to open the front cover of the Universal transceiver by pushing the retaining clip
on the top downward. This allows the hinged cover to drop down and expose the circuit board.
3. Carefully pull the circuit board free from the pins on the enclosure.
4. Pull the plastic battery tab on the Universal transceiver to activate the battery.
5. Return the circuit board onto the two pins.
6. Snap the front cover of the Universal transceiver back into place.
7. Return the Universal transceiver to its place inside the Nurse Call enclosure.
NOTE: The Universal transceiver integrates with the Nurse Call. Refer to “Universal
Transceiver” on page 29 for information on the LED light, tamper functionality and
replacing the battery.
Universal Transceiver* Nurse Call Terminal
NO C1
GND C2
NC S2