User Manual

Chapter 2: Installing Transceiver Devices
30 9600 Series Wireless Call System (0510-1078-D) - Hardware Installation Guide
To mount the Universal transceiver using mounting hole
1. Use your fingers to open the front cover of the transceiver by pushing the retaining clip on the top
downward. This allows the hinged cover to drop down and expose the circuit board.
2. Carefully pull the circuit board free from the pins on the enclosure.
3. Drill a 1/8 inch mounting hole through the indentation in the transceiver
enclosure.
4. Using the enclosure of the Universal transceiver as a template, place it
level against the wall and mark the location of the mounting hole.
5. Mark out the mounting hole and drill a 1/16 inch diameter hole where
you made the mark.
6. Line up the hole on the transceiver enclosure with the newly drilled hole
and mount the enclosure to the door frame using a number 6 screw (not
included).
7. Pull the plastic battery tab to activate the battery or refer to the section
entitled “To replace the battery in a Universal transceiver” on page 31
to insert a new battery.
8. Return the circuit board onto the two pins.
9. Snap the front cover of the transceiver back into place.
To mount the Universal transceivers with adhesive pad
The Universal transceiver can be attached using an adhesive pad that can be
purchased with the transceiver.
1. Remove an adhesive pad from the strip of paper.
2. Place the transceiver face down.
3. Line the adhesive pad up with the back of the transceiver.
4. Apply the adhesive pad.
5. Verify that the pad is applied correctly and is not hanging over the sides
of the transceiver.
6. Determine where you want to apply the transceiver. The surface must be clean, dry and free of
condensed moisture.
7. Pull the plastic battery tab to activate the battery or refer to the section entitled “To replace the
battery in a Universal transceiver” on page 31 to insert a new battery.
8. Remove the adhesive plastic guard.
9. Firmly attach the transceiver to the mounting surface. Ideal application temperature range is 70°F to
100°F (21°C to 38°C).
10. Press firmly and hold for approximately 10 seconds to activate the pressure sensitive adhesive.
11. After application, the bond strength will increase as the adhesive flows onto the surface. At room
temperature, approximately 50% of ultimate bond strength will be achieved after 20 minutes, 90%
after 24 hours and 100% after 72 hours.
Drill hole