User's Manual
Table Of Contents
- Important Warnings
- Bio-Incompatibility Notice
- Compliance
- Federal Communication Commission (FCC) Compliance
- Industry Canada Compliance
- Overview
- 9450 System
- Quick Response (QR) Wired System
- 9500 Series Wired Call System
- 9600 Series Wireless Call System
- Intended Audience
- Additional Detailed Documentation
- Contact Information
- Product Warranty
- Chapter 1
- Introduction
- Central Server and Client Computers
- Quick Look Display
- 9450 System
- Staff Alert Panel
- Exit Alarm Controller
- Card Reader Access Device
- The Exit Alarm Zone
- Exit Alarm Receiver
- Magnetic Reed Switch
- CodeLock Electromagnetic Lock
- Alarming Band Receivers
- Alarming Band Zone
- Alarming Band Transmitters
- Patient and Infant Transmitters
- Smart Sense™ Infant Transmitter and Banding Material
- Mother Transmitter
- Wander Management Transmitter
- CodeWatch Transmitter
- Quick Response System
- Wireless Receiver
- Repeater
- Locator
- Paging Base
- Back-Up Interface
- Pendant Transmitter
- Wall Mount Transmitter
- Pull Cord
- Check-in Pull Cord
- Smoke Detector
- PIR Sensor
- Door/Window Transmitter
- Universal Transmitter
- 9600 Series Wireless Call System
- Gateway
- Router
- Quick Look Router
- 32 Channel Controller Router
- Dome Light
- Transceivers
- Pull Cord
- Check-in Pull Cord
- Wall Mount Emergency Call
- Nurse Call Transceiver
- Universal Transceiver
- Universal Nurse Call
- Door/Window Transceiver
- Smoke Detector
- PIR Sensor
- Pendant Transceiver
- 9500 Series Wired System
- Central Power Supply
- 32 Zone Staff Alert Panel
- Dome Light
- Assistance Call Devices
- Nurse Call
- Pull Cord
- Fall Management System
- Fall Management System Control Unit
- Fall Management System Sensor Pad
- Fall Management System Nurse Call
- Advanced 3-Way Care Solution
- Advanced 3-Way Control Unit
- Advanced 3-Way Care Sensor Pads
- Motion Sensor Pad
- Incontinence Sensor Pad
- Advanced 4-Way Care Solution
- Advanced 4-Way Control Unit
- Advanced 4-Way Care Sensor Pads
- Motion Sensor Pad
- Incontinence Sensor Pad
- Messaging Services
- Event Messaging
- Messaging Delays, Retries and Escalation
- Walkie-Talkie
- Chapter 2
- Introduction
- Start the Software
- Sleep Mode
- Window Conventions
- Touchscreen Monitor
- Quick Reference Tutorial
- Map Orientation
- Ruleset for Displaying Patient Name
- The Main Window
- Functions
- Event List
- Census
- Map
- Devices Displayed on the Map
- Help
- Silence
- Alarm Message Box
- Low Battery Icon
- Chapter 3
- Introduction
- Commonly Used Terms
- Login and Passwords
- Device Supervision
- Inactivity Check-in
- Units
- Global Lockdown
- Troubleshooter
- Admit Functions
- Name An Auto-Enrolled Transmitter
- Manual Admit
- Pre-Enroll
- Admit Information Windows
- Admit Information Tabs
- Quick Look Tab
- Main Tab
- Medical Tab
- Contact Tab
- Insert a Picture
- Enter Transmitter Information
- Scheduling an Event
- Discharge
- Adjust
- Escort
- Transfer
- Update Record
- Administrative Functions
- Add/Update An Asset
- Asset Main Information Tab
- Staff Drill
- System Maintenance
- Changing Client Properties
- Configuration
- Reports
- Messaging Functions
- Scheduled Messages
- Changing Shift
- Start Shift
- End Shift
- Send Message
- Chapter 4
- Introduction
- Events
- Event Information Window
- Event Information Window Properties
- Event Types
- Red Alarms
- Door Alarm
- Exit Alarm (Wide Gap)
- Smoke Alarm
- Perimeter Alarm
- Cut Band Alarm
- Band Off Alarm
- Mismatch Alarm
- Match Alarm
- Link Alarm
- Check Alarm
- No Signal Alarm
- Assistance Required Alarm
- Fall Alarm
- Wet Alarm
- Turn Alarm
- Server Missing Alarm
- Yellow Alarms
- No Signal Alarm (9600 Series Pendant)
- Client Missing
- Device Fault
- Low Battery
- Tamper Alarm
- White Alarms
- Auto-Enroll
- Admit Completed
- Pre-Enroll Expired
- Discharge Expired
- Discharge Completed
- Escort to Expire
- Escort Expired
- Escort Completed
- Transfer to Expire
- Transfer Expired
- Transfer Completed
- Begin Adjust
- Adjust Expired
- Adjust Competed
- Scheduled Event
- Blue Alarms
- Door Alarm
- Cut Band Alarm
- No Signal Alarm
- Light Blue Alarms
- Admit Completed
- Discharge Expired
- Discharge Completed
- Escort to Expire
- Escort Expired
- Escort Completed
- Transfer to Expire
- Transfer Expired
- Transfer Completed
- Adjust Expired
- Adjust Completed
- Scheduled Event
- Chapter 5
- Introduction
- Reports
- Report Buttons
- Sort By Headings
- Additional Joint Commission Report Buttons
- System Reports
- Daily Alarms and Activities (Tracer Level 2)
- Alarm Report
- Alarm Activities Report
- Alarm Response Report
- Care Time Report (Code Alert only)
- Activities Report
- All Activities Report
- All Other Reasons Report
- Facility Trends (Tracer Level 3)
- Joint Commission Alarm Trend Report
- Joint Commission Assistance Trend Report
- Response Time Trend Report
- Staff Reports (Tracer Level 4)
- Users Report
- User Training Report
- Staff Care Time Report (Code Alert only)
- Staff Drill Report
- Training Report
- Facility Maintenance (Tracer level 5)
- System Maintenance Report
- Low Batteries Report
- Device Fault Report
- Additional Reports
- Census Report
- Auto Enrolled History Report
- Adjusted Bands Report
- Transfer Report
- Escort Report
- Discharge Report
- Device Hardware Report
- Device Tree Report (Code Alert only)
- Transmitter Report
- Links Report
- Links Activities Report
- Sensatec Report
- Patient Reports
- Review Info Report
- Review Activity Report
- Review Response Report
- Review Response Reason
- Review Response Reason Detail Report
- Asset Reports
- Asset Transmitter Report
- Asset Activities Report
Chapter 3: Using the Software
62 Series 7.0 Software (0510-1086-B) - User Guide
Configure Band Off
The default Band Off settings are configured at the Unit Properties level (refer to Configure Units in the
Series 7.0 Administrator Manual). However, the default settings for Band Off can be changed for each
transmitter being admitted using the Configure option.
To configure the Band Off settings
1. Click the Configure button on the Main Tab of the Admit screen.
The Configure Transmitter window opens.
2. Click the Band Off Alarm Enabled checkbox to enable/disable the Band Off feature for the
transmitter being admitted.
3. To restore the Unit’s current defaults, click the Restore Unit Defaults button.
4. To change a transmitter’s settings for generating a Band Off alarm, select any valid combination of
Combined Alarm radio buttons and the Alarm on Any checkboxes. From the Combined Alarm,
each parameter must have a value of And, Or, or Off.
a. Click the And radio button next to a parameter to select it as “one” of the required parameters
for a Band Off alarm. At least one other parameter must be set to And to generate a Band Off
alarm (i.e. Capacitance and Resistance). You can also select And for one parameter and Or
for at least two other parameters to generate a Band Off alarm (i.e. Temperature and
Capacitance or Resistance).
b. Click the Or radio button next to a parameter to select it as “one” of the required parameters
for a Band Off alarm. At least one other parameter must be set to Or to generate a Band Off
alarm (i.e.Resistance or Temperature).
c. Click the OFF radio button next to a parameter to select it as a parameter that will not be used
for determining a Band Off alarm.
5. Click the Alarm On Any check box next to a parameter to individually choose it to generate a
Band Off alarm.
6. The Band Off Delay settings can also be changed for each parameter. Once a Band Off condition
is met, the alarm will be delayed for the configured time. If the Band Off condition resolves within
the delayed time, the Band Off alarm will not be sent. For Combined Alarms, the parameter with
the longest delay takes precedence.
NOTE: The Configure button will not be present if Band Off alarms are not enabled for the
currently assigned unit.
Parameters:
• Capacitance—the change in contact between
transmitter and infant’s extremity
• Resistance—the stretch of the banding material
• Temperature—the change in transmitter
temperature