User's Manual
Table Of Contents
- Important Warnings
- Bio-Incompatibility Notice
- Compliance
- Federal Communication Commission (FCC) Compliance
- Industry Canada Compliance
- Overview
- 9450 System
- Quick Response (QR) Wired System
- 9500 Series Wired Call System
- 9600 Series Wireless Call System
- Intended Audience
- Additional Detailed Documentation
- Contact Information
- Product Warranty
- Chapter 1
- Introduction
- Central Server and Client Computers
- Quick Look Display
- 9450 System
- Staff Alert Panel
- Exit Alarm Controller
- Card Reader Access Device
- The Exit Alarm Zone
- Exit Alarm Receiver
- Magnetic Reed Switch
- CodeLock Electromagnetic Lock
- Alarming Band Receivers
- Alarming Band Zone
- Alarming Band Transmitters
- Patient and Infant Transmitters
- Smart Sense™ Infant Transmitter and Banding Material
- Mother Transmitter
- Wander Management Transmitter
- CodeWatch Transmitter
- Quick Response System
- Wireless Receiver
- Repeater
- Locator
- Paging Base
- Back-Up Interface
- Pendant Transmitter
- Wall Mount Transmitter
- Pull Cord
- Check-in Pull Cord
- Smoke Detector
- PIR Sensor
- Door/Window Transmitter
- Universal Transmitter
- 9600 Series Wireless Call System
- Gateway
- Router
- Quick Look Router
- 32 Channel Controller Router
- Dome Light
- Transceivers
- Pull Cord
- Check-in Pull Cord
- Wall Mount Emergency Call
- Nurse Call Transceiver
- Universal Transceiver
- Universal Nurse Call
- Door/Window Transceiver
- Smoke Detector
- PIR Sensor
- Pendant Transceiver
- 9500 Series Wired System
- Central Power Supply
- 32 Zone Staff Alert Panel
- Dome Light
- Assistance Call Devices
- Nurse Call
- Pull Cord
- Fall Management System
- Fall Management System Control Unit
- Fall Management System Sensor Pad
- Fall Management System Nurse Call
- Advanced 3-Way Care Solution
- Advanced 3-Way Control Unit
- Advanced 3-Way Care Sensor Pads
- Motion Sensor Pad
- Incontinence Sensor Pad
- Advanced 4-Way Care Solution
- Advanced 4-Way Control Unit
- Advanced 4-Way Care Sensor Pads
- Motion Sensor Pad
- Incontinence Sensor Pad
- Messaging Services
- Event Messaging
- Messaging Delays, Retries and Escalation
- Walkie-Talkie
- Chapter 2
- Introduction
- Start the Software
- Sleep Mode
- Window Conventions
- Touchscreen Monitor
- Quick Reference Tutorial
- Map Orientation
- Ruleset for Displaying Patient Name
- The Main Window
- Functions
- Event List
- Census
- Map
- Devices Displayed on the Map
- Help
- Silence
- Alarm Message Box
- Low Battery Icon
- Chapter 3
- Introduction
- Commonly Used Terms
- Login and Passwords
- Device Supervision
- Inactivity Check-in
- Units
- Global Lockdown
- Troubleshooter
- Admit Functions
- Name An Auto-Enrolled Transmitter
- Manual Admit
- Pre-Enroll
- Admit Information Windows
- Admit Information Tabs
- Quick Look Tab
- Main Tab
- Medical Tab
- Contact Tab
- Insert a Picture
- Enter Transmitter Information
- Scheduling an Event
- Discharge
- Adjust
- Escort
- Transfer
- Update Record
- Administrative Functions
- Add/Update An Asset
- Asset Main Information Tab
- Staff Drill
- System Maintenance
- Changing Client Properties
- Configuration
- Reports
- Messaging Functions
- Scheduled Messages
- Changing Shift
- Start Shift
- End Shift
- Send Message
- Chapter 4
- Introduction
- Events
- Event Information Window
- Event Information Window Properties
- Event Types
- Red Alarms
- Door Alarm
- Exit Alarm (Wide Gap)
- Smoke Alarm
- Perimeter Alarm
- Cut Band Alarm
- Band Off Alarm
- Mismatch Alarm
- Match Alarm
- Link Alarm
- Check Alarm
- No Signal Alarm
- Assistance Required Alarm
- Fall Alarm
- Wet Alarm
- Turn Alarm
- Server Missing Alarm
- Yellow Alarms
- No Signal Alarm (9600 Series Pendant)
- Client Missing
- Device Fault
- Low Battery
- Tamper Alarm
- White Alarms
- Auto-Enroll
- Admit Completed
- Pre-Enroll Expired
- Discharge Expired
- Discharge Completed
- Escort to Expire
- Escort Expired
- Escort Completed
- Transfer to Expire
- Transfer Expired
- Transfer Completed
- Begin Adjust
- Adjust Expired
- Adjust Competed
- Scheduled Event
- Blue Alarms
- Door Alarm
- Cut Band Alarm
- No Signal Alarm
- Light Blue Alarms
- Admit Completed
- Discharge Expired
- Discharge Completed
- Escort to Expire
- Escort Expired
- Escort Completed
- Transfer to Expire
- Transfer Expired
- Transfer Completed
- Adjust Expired
- Adjust Completed
- Scheduled Event
- Chapter 5
- Introduction
- Reports
- Report Buttons
- Sort By Headings
- Additional Joint Commission Report Buttons
- System Reports
- Daily Alarms and Activities (Tracer Level 2)
- Alarm Report
- Alarm Activities Report
- Alarm Response Report
- Care Time Report (Code Alert only)
- Activities Report
- All Activities Report
- All Other Reasons Report
- Facility Trends (Tracer Level 3)
- Joint Commission Alarm Trend Report
- Joint Commission Assistance Trend Report
- Response Time Trend Report
- Staff Reports (Tracer Level 4)
- Users Report
- User Training Report
- Staff Care Time Report (Code Alert only)
- Staff Drill Report
- Training Report
- Facility Maintenance (Tracer level 5)
- System Maintenance Report
- Low Batteries Report
- Device Fault Report
- Additional Reports
- Census Report
- Auto Enrolled History Report
- Adjusted Bands Report
- Transfer Report
- Escort Report
- Discharge Report
- Device Hardware Report
- Device Tree Report (Code Alert only)
- Transmitter Report
- Links Report
- Links Activities Report
- Sensatec Report
- Patient Reports
- Review Info Report
- Review Activity Report
- Review Response Report
- Review Response Reason
- Review Response Reason Detail Report
- Asset Reports
- Asset Transmitter Report
- Asset Activities Report
Series 7.0 Software (0510-1086-B) - User Guide 117
Event Types
Transfer to Expire
This alarm occurs when the time allowed for a patient to be transferred will expire in the configured time (if
the allotted time was configured for greater than 15-minutes) and the alarming band transmitter, in the
Transfer mode, has not been moved from one protected area to another.
To respond to a Transfer to Expire
1. Determine the location of the patient.
2. If the patient is secure and will not be transferred to a protected area soon, clear the Transfer to
Expire alarm and reset the duration time for the Transfer.
3. If the patient has not yet been moved, clear the Transfer to Expire alarm and cancel the Transfer.
Transfer Expired
This alarm occurs when the selected amount of time required for a patient to be transferred has expired and
the alarming band transmitter, in the Transfer mode, has not reached its destination.
To respond to a Transfer Expired Alarm
1. Determine the location of the patient.
2. From the Client computer, click anywhere in the Transfer Expired Alarm Message Box to access
the Event Information window.
3. Select one of the following event causes:
• Patient Delayed—the patient was delayed and needs more time for the transfer.
• Failed to Start—the Transfer was never started; or the patient was never transferred.
• Transfer Completed—the patient was successfully transferred to the destination.
• Te s t—the system was being tested.
• Other—opens a Clear Reason window, user must enter the cause in this window.
You cannot clear an event until you select the appropriate cause for the event.
4. If the patient has not yet been transferred, perform the Transfer function again.
5. If the patient has left the initial unit but has not arrived at the transfer unit:
a. Bring the patient through the door of the unit to which they are being transferred; a Door
Alarm may occur.
b. Follow the procedures for handling a Door Alarm (refer to “Door Alarm” on page 98).
c. Select Transfer problem for the cause of the Door Alarm.
d. If No Signal alarms occur, contact an Administrative user to manually transfer the transmitter
to the new unit.
Transfer Completed
This alarm occurs when a Transfer for a patient is completed. This dialog box only appears if the software has
been configured to confirm the transfer.The Confirm Transfer is configured in the Configuration, Global
Settings menu (refer to the Series 7.0 Software Administrator Guide).