Install Instructions
Built to Last – Industrial-Grade Design
` Multiple voltage capability allows the system to operate on 120, 208 or 240 VAC single-phase.
` Continuous operation is suggested, but the unit can also be activated only when only the blower is
operating.
` Dual lamps provide ample UV-C with individual bulb indicators to tell you when to change the
lamps—Typically, every year.
` UV-C bulbs are specially coated to prevent any ozone formation.
(Ordinary UV-C
bulbs can create harmful ozone).
` PCO surface is cleanable, allowing the catalyst to be renewed with simple cleaning (recommend to
be cleaned when UV-C bulbs are changed).
Normally the AC/PP purier would need to be changed frequently to treat the whole home,
but the UV/PCO combination greatly reduces the load on the AC/PP purier, allowing the
purier to clean the air for extended periods. The AC/PP purier should be changed annually.
Installation Instructions
THIS UNIT IS ONLY TO BE INSTALLED BY PROPERLY TRAINED AND LICENSED HVAC TECHNICIANS.
IT IS THE TECHNICIAN’S RESPONSIBILITY TO PROPERLY INSTRUCT THE HOMEOWNER
OF THE DANGERS OF LOOKING DIRECTLY AT THE LIGHT EMITTED FROM THE UNIT.
Step 1. Verify the contents of the package.
The QwikPure TripleGuard™ kit contains the following:
If you are missing any parts contact Mainstream Engineering Corp.® for a replacement
at 1-800-866-3550 or 1-321-631-3550.
Two replaceable UV-C bulbs
ON/OFF power switch
Photocatalytic
oxidation surfaces
Green system ON-LED,
Dual orange LEDs to indicate proper
UV bulb function (one for each UV-C bulb)
E
lectronics control module
AC/PP access plate
Replaceable Activated Carbon
Potassium Permanganate
Purier
` QwikPure TripleGuard™ air
sanitization unit for HVAC duct
mounting
` Replaceable AC/PP purier
(packaged separately)
` 2 replaceable UV-C bulbs
(packaged separately)
` Mounting ange assembly
(Interior ange, four wing nuts,
two ¼-20 nuts and fender
washers)
` Caution UV-C In Use Decal
` Next Service Date sticker
` Two fuse assemblies with fuses
` One rubber grommet
` Installation and Operation Manual
` Warranty registration card