Installation guide
Connecting tank
• N.B.  Do not switch on the Quooker until the tank is filled with water.
• The Quooker tank is supplied with a 3-core mains cord with earthed plug.  
All that is required is an earthed socket close to the appliance.
•  The Quooker tap is fitted with an indicator lamp which indicates whether or
not the heating element is heating.
1 2
3 4
1 Connecting
tank
Place the Quooker in position and 
connect it to the inlet combination
with the fibre ring supplied.
2 Connecting tap
Connect the other short hose to 
the tap in the same way with the fibre
ring supplied.
3 Flushing tank
Open the Quooker tap. Now open 
the main tap and the tap of the inlet 
combination. Check for leaks. 
Flush the Quooker through for a few
minutes until the water is clear. 
Black water will flow out first. This is
Norite carbon from the filter and is,
incidentally, completely harmless.
4 Electrical 
connection
To connect the indicator lamp insert
the plug into the hole provided.
Connect the tank to an earthed socket
and do not switch it on until the tank
is filled with water. The ‘Q’ button on
top of the tank is the on/off - switch.
After the Quooker has heated up, the
entire content of boiling water must
be flushed out once before use.
E