Package Contents
Warnings and Cautions
Turn off electricity at circuit breaker or main fuse box before installation. Consult a licensed electrician if in doubt.
These instructions are provided for your safety. It is very important you read them completely before installing the fixture. We strongly
recommend that a licensed, professional electrician perform the installation.
Disconnect fixture from power source before replacing bulbs. Make sure bulbs are given sufficient time to cool before removal.
A
Crossbar
Assembly
x1
Pleasegoto forproductcleaningtips.Gotothe selection.
(4)B10CandelabraBasebulbs60WMaximum,CandelabraBaseT8Vintage Bulbs are recommended, bulbs not included..
20-30minutes
Identifyandinspectallpartsbeforebeginninginstallation.Checkpackagecontentlistanddiagramsbelowtoensureallpartsare
present.Ifanypartsaremissingordamaged,donotattempttoassemble,install,oroperatethefixture.Contactyouroriginalplaceofpurchase.
www.quoizel.com Care+Maintenance
LightSource:
EstimatedAssemblyTime:
Preparation:
ToolsRequired: Flathead screwdriver, Phillips screwdriver, pliers, wire cutters, wire strippers, electrical tape, safety glasses.
Installation Guide #IS-QF4059K
F
Fixture Body
x1
B
Lock Screw
x4
2018 QuoizelInc.
ReleasedDate:2018-10-18
visit us on-line at www.quoizel.com
Cage
x1
G
Triangle
Glass Panel
x4
C
Rectangle
Glass Panel
x4
D
Square
Glass
Panel
x1
E
STEP 1 - Install the Square Glass Panel
A. Place the Square Glass Panel (E) into the bottom of the Cage (G)
and secure by folding tabs in the bottom edge.
E
G
Tab
Figure 1
STEP 2 - Install Triangle Glass Panels and Rectangle Glass
Panels
A. Place Triangle Glass Panels (C) and Rectangle Glass Panels (D)
into the side of the Cage (G) and secure by folding tabs in the edge.
G
D
C
Tab
Tab
Figure 2
STEP 3 - Install the Crossbar Assembly to Outlet Box and Adjust
the length of the Nipple
A. Attach the Crossbar Assembly (A) to the Outlet Box with the head of
the Green Ground Screw facing you. Secure it with Outlet Box
Screws (not included), tighten until snug
B. Adjust the hex nut and lock washer underside of the crossbar to the
middle of the nipple.
C. Remove the mounting ball from the nipple. Place the Fixture Body
(F) over the nipple against the ceiling to determine the correct
position of the nipple. Thread the mounting ball onto the nipple.
Adjust the nipple to allow the Fixture Body (F) to rest against the
ceiling when held in place by the mounting ball.
D. Remove the mounting ball and the Fixture Body (F). Tighten the
lock washer and the hex nut against the crossbar to secure in place.
.
Hex Nut and
Lock Washer
Nipple
Green Ground Screw
Outlet Box Screw
(not included)
Mounting Ball
A
F
Figure 3