Installation Guide
2of2
Step 3.
F. Raise the Ceiling Canopy (D) and canopy lock ring up the Fixture
Chain (B) and over the canopy chain loop. Tighten the canopy
lock ring onto the canopy chain loop until tight.
Suggested chain length for Ceiling height :
8’ ceiling : use 15 links of chain and 2 quick links
9’ ceiling : use 26 links of chain and 2 quick links
10’ ceiling : use 37 links of chain and 2 quick links
Figure 3
STEP 3 - Making the Wire Connections
A. Wrap bare or green ground wire around green ground screw on the
crossbar, no less than 2 inches from the end of the wire. Tighten the
green ground screw.
Use standard wire connectors (G) to make all wire connections.
Twist connectors until wires are tightly joined together. Wrap each
connection with approved electrical tape and carefully stuff all the
connected wires into outlet box.
Note: If the electrical wire is going to be cut shorter than provided
you will need to identify the "L" line wire and the "N" neutral wire
before you cut the excess wire off. One is labeled N and the other
labeled L. To do this separate the "L" line wire and the "N" neutral
wire as far as you need to. Re-label the wire near where you want to
make the cut. Be sure to mark the wire on the side of the fixture and
not on the excess wire being cut and removed.
B.
Green Ground Screw
on the Crossbar
White wire
from outlet box
White wire from fixture
identified with the Label “N”
Black wire from
outlet box (or Red)
Black wire from fixture
identified with the label “L”
Bare, or Green
Ground wire
from outlet box
Ground wire
from Fixture
STEP 4 Install Shade and Bulb-
A. Place Shade (H) and Steel Collar (I)
over the Socket, secure by threading
Socket Collar (J) onto Socket. Hand
tighten until sung.
B. Insert bulb and screw snugly into
place.
Your fixture is now assembled and
ready to use. Enjoy!
Figure 6
Socket
H
I
J
Vintage Bulb
(recommended
but not supplied)
2018 QuoizelInc.
ReleasedDate:2018-11-12
visit us on-line at www.quoizel.com