Instructions

Model No.
Date
QU-TK-F3x
2019/1/10
1.03
Communication Protocol
QUIO
Ver.
Page
QU-TK-F3 Series
39 / 52
9
.10.4.3 Modify sector key (KEY A)
HOST Command
C” 60H 33H 00H D5H
00H
sn
lc
p-data
Positive response
P” 60H 33H
st0
e1
st1
e0
st2
r-data
Negative response
N” 60H 33H
Modify sector key (key A)
This command only can modify KEY A, an d modify KEY B as 0xFF, 0xFF,
xFF,0xFF,0xFF,0xFF in the meantime modify control words as 0xFF, 0x07, 0x80, 0x69” (ex-
0
work default)
Use block command to modify Key A, Key B control word
sn (1byte):
lc (1byte):
p-data:
sector number (S50 card sn=00H-0FH, S70 card sn=00H-27H)
password length lc=06H
password data 6 bytes.
return data
r-data (2 byte):
(positive response with data 9000H, and negtive response with sw1+sw2”)
9
.10.4.4 Download password to EEPROM
HOST Command
C” 60H 33H 00H
D0H
st1
ks
sn
lc
p-data
Positive response
P” 60H 33H
st0
e1
st2
r-data
Negative response
N” 60H 33H
e0
Read key from EEPROM of RF module and verify the sector key
EEPROM can preserve 32 groups of key data
ks(1byte):
key select (Key A=00H Key B=01H)
sector number (sn=00H-0FH)
password length lc=06H
sn (1byte):
lc(1byte):
p-data (6 byte):
r-data (2 byte):
password data
return data .
positive response sw1+sw2=9000H.
negative response sw1+sw2=6F00H
9
.10.4.5 Read sector data
HOST Command
C” 60H 33H 00H B0H
sn
bn
le
QUIO
https://www.quio-rfid.de Email: kontakt@quio-rfid.de