Instructions

Model No.
Date
QU-TK-F3x
2019/1/10
1.03
Communication Protocol
QUIO
Ver.
Page
QU-TK-F3 Series
28 / 52
Protection condition can be set up at one time in the data which continued in the main memory.
9
.8.4.6 Data write to security memory on SLE4442
HOST Command
C” 53H 33H 00H
D0H
st1
02H abH
cdH
efH…
Positive response
P” 53H 33H
st0
e1
st2
data
Negative response
N” 53H 33H
e0
Notes: ab H: the start address to write data in the main memory
cd H: the length of bytes of data to write
ef H: the data to write first (cd H bytes)
After a password check is finished normally, the Reference-Data area of 3byte can be
changed.
All 32bits are handled as 4bytes. How to change the Reference-Data is as the following.
ex). "CR3"+ 00D0020103123456
After command execution, ICRW returns response with 9000H or sw1+sw2 as the result.
Notes: Better not ot writ, because the Error-counter is always allowed to write and easily make
a failure. Error-Counter is controlled when password is checked.
9
.8.4.7 Verification data present to SLE4428
HOST Command
C” 53H 33H 00H 20H 03H 01H 03H
efH…
Positive response
P” 53H 33H
st0
e1
st1
e0
st2
data
Negative response
N” 53H 33H
Notes: ef H: the data to compare (3bytes)
Before changing data, password must be check
Because this function should be made effective, the issue of the next command is necessary.
Ex) “CR3” +0020030103xxxxxx (xxxxxx: security code 3bytes)
Card will verify password between card and command.
A user must know password at least when a user wants to rewrite the data on SLE4442 card.
Error-Counter can be reset in the zero if password is given to SLE4442 card properly if the
value of Error-Counter is 2 or less.
QUIO