Instructions

Model No.
Date
QU-TK-F3x
2019/1/10
1.03
Communication Protocol
QUIO
Ver.
Page
QU-TK-F3 Series
23 / 52
9.7.8 Select SAM
HOST Command
C” 52H 40H
SAMn
st1
Positive response
P” 52H 40H
st0
e1
st2
Negative response
N” 52H 40H
e0
HOST can select SAM 1,2,3,4 or 5.
Sel = 30H: SAM 1.
Sel = 31H: SAM 2. (option)
Sel = 32H: SAM 3. (option)
Sel = 33H: SAM 4. (option)
Sel = 34H: SAM 5. (option)
SAM command is effective only in the module selection.
When Initialize command is executed, SAM 1 will be selected.
9.8 SLE4442/4428 Control
9
.8.1 SLE4442/4428 Reset
HOST Command
C” 53H 30H
Positive response
P” 53H 30H
st0
e1
st1
e0
st2
ATR(4 byte)
Negative response
N” 54H 30H
The QU-TK-F31 supplies power (VCC) and clock (CLK), then reset (RST) release. After reset, return
ATR.
ATR: SLE4442 Card ATR=“A2H13H10H91H”
SLE4442 Card ATR=“92H23H10H91H
9
.8.2 Deactivate SLE4442/4428
Command
C” 53H 31H
QUIO
https://www.quio-rfid.de Email: kontakt@quio-rfid.de