Instructions

Model No.
Date
QU-TK-F3x
2019/1/10
1.03
Communication Protocol
QUIO
Ver.
Page
QU-TK-F3 Series
19 / 52
Warm Reset keeps the card activated and get the ATR again.
Type: CPU Card communication protocol
=
30H
31H
T=0 Protocol
T=1 Protocol
=
9
.6.7 Automatic APDU Transmission for either T=0 or 1
HOST Command
C” 51H 39H
C-APDU
Positive response
P” 51H 39H
st0
st1
e0
st2
R-APDU
Negative response
N” 51H 39H
e1
Card Protocol is detected automatically (T=0 or 1) and target C-APDU is sendt Set data to “C-
APDU”. QU-TK-F31 returns “R-APDU” data to HOST.
An error “60” is returned when a power failure is detected.
If protocol type of IC card is not T=0, error code “62”is sent.
If IC Card does not respond within Working Wait Time, QU-TK-F31 deactivates an IC card and
error code 63” is sent.
If any other protocol error occurs, machine deactivates an IC card and error code “64” is sent.
If HOST tries to communicate before IC card activation, error code “65” is sent.
9.7 SAM Card Operation
9
.7.1 Active SAM Command
HOST Command
C” 52H 30H
Vcc
st0
e1
Positive response
P” 52H 30H
st1
e0
st2
Type
ATR
Negative response
N” 52H 30H
ATR
The QU-TK-F31 supplies power (VCC) and clock (CLK), then reset (RST) release.
Type: SAM protocol type
=30H T=0 protocol
=31H T=1 protocol
QUIO
https://www.quio-rfid.de Email: kontakt@quio-rfid.de