Instructions
Model No.
Date
QU-TK-F3x
2019/1/10
1.03
Communication Protocol
QUIO
Ver.
Page
QU-TK-F3 Series
18 / 52
9
.6.5 T=0 CPU Card APDU Transmission
HOST Command
“
C” 51H 34H
C-APDU
Positive response
“
P” 51H 34H
st0
st1
e0
st2
R-APDU
Negative response
“
N” 51H 34H
e1
This exchanges data between CPU card by protocol T=1
Dispenser should follow T=1 protocol to combine C-APDU as I-block and send to CPU card. CPU
card should return R-APDU to HOST
C-APDU
CLA INS P1 P2 Lc Data1 … Data (Lc) Le
NAD PCB LEN CLA INS P1 P2 Lc Data1
…
Data (Lc) Le EDC
End block
I-block
Head block
Information block
QU-TK-F31 returns “R-APDU” data to HOST
Head block
Information block
End block
Data (Lc) Le EDC
I-block
NAD PCB LEN CLA INS P1 P2 Lc Data1
…
CLA INS P1 P2 Lc Data1
…
Data (Lc) Le
R-APDU
Error code “60” is returned on power failure.
If protocol type of IC card is not T=0, error code “62” returns.
If ICC won’t respond within valid Wait Time, machine deactivates card and returns error code “63”.
If protocol error occurs, machine deactivate IC card and returns error code “64”.
If HOST communicates before IC card activation, error code “65” returns.
Note: Refer to ISO/IEC7816-3 for more details of T=1 APDU and get C-APDU information from the
Card COS manual.
9
.6.6 CPU Card Warm Reset
HOST Command
“
C” 51H 38H
Positive response
“
P” 51H 38H
st0
e1
st1
e0
st2
Type
ATR
Negative response
“
N” 51H 38H
QUIO