9. Command Description
9
.1 Reset/Initialization
HOST Command:
C” 30H Pm
Positive Return:
P” 30H Pm
st0
e1
st1
e0
st2
Firmware Version
Negative Return:
N” 30H Pm
This is the first necessary command after powering on and can be executed anytime during operation.
On first run, dispenser will check and adapt to host baud rate.
After this command, error code will be cleared, and machine will be reset to default status (e.g.
Insertion Card from front will be disabled).
Pm: Command parameter
If there is no card in card channel, motor rotates slightly for self-test
If there is a card inside channel, the following parameters may be applied:
3
3
3
3
3
3
0H: Move and Hold the card at gate;
1H: Capture Card to Error Card Bin;
3H: No Movement, Retain the Card Inside;
4H: As 30H, and Error Card Counter increment;
5H: As 31H, and Error Card Counter increment;
7H: As 33H, and Error Card Counter increment;
Firmware Version: E.g. QU-TK-F31-V1.10