User Manual (Version 1.2.
Table of Contents 1 Getting Started ..................................................................................................................................................................................3 1.1 About This Guide..............................................................................................................................................................................................3 1.2 Barcode Scanning................................................................
5.2.6 Interleaved 2 Of 5.................................................................................................................................................................................. 31 5.2.7 Matrix 2 Of 5 .......................................................................................................................................................................................... 32 5.2.8 Industrial 2 Of 5.........................................................................
1 Getting Started 1.1 About This Guide This guide provides programming instructions for the QUIO 2D Barcoder Readers: RT830A, RT860 RT870. Users can configure the QUIO 2D Barcoder Reader by scanning the programming barcodes included in this manual.
2 Communication Interfaces 2.1 USB COM Port Emulation With USB interface, scan the USB COM Port Emulation setting code allows the Host to receive data in the way as a serial port does. A driver is required for this feature. USB COM Port Emulation Default serial communication parameters are listed below. Make sure all parameters match the host requirements.
2.2 Baud Rate Baud rate is the number of bits of data transmitted per second. Set the baud rate to match the Host requirements.
2.3 Data Bit & Parity Check & Stop Bit Note: some products only allows default configuration (None Parity/8 Data Bits/1 Stop Bit), configuration command: 0607032; If products do not support multiple configurations, scanning the bar code of non-default configuration would error beep.
2.4 USB HID-KBW When you connect the s c a n n e r to the Host via a USB connection, you can enable the USB HID-KBW feature by scanning the barcode below. Then scanner’s transmission will be simulated as USB keyboard input. The Host receives keystrokes on the virtual keyboard. It works on a Plug and Play basis and no driver is required. USB HID-KBW (Default) 2.5 USB Country Keyboard Types Keyboard layouts vary from country to country. The default setting is 1-U.S. keyboard. 1 – U.S.
6 – Turkey_F 7 – Italy 8 – Norway 9 – Albania 10 – Belgium 11 – Bosnia 12 – Brazil 13 – Croatia 14 – Czech 15 – Dutch 8
16 – Estonia 17 – Germany 18 – Greek 19 – Hungary 20 – Irish 21 – Latvia 22 – Lithuania 23 – Macedonia 24 – Spain 25 – Poland 9
26 – Portugal 27 – Romania 28 – Russia 29 – Japan 10
2.6 Convert Case Scan the appropriate barcode below to convert barcode data to your desired case. No Case Conversion (Default) Convert All To Upper Case Convert All To Lower Case Example: When the Convert All to Lower Case feature is enabled, barcode data “AbC” is transmitted as “abc”. 2.7 RS232 Interface If you use the scanner with USB cable firstly, and you want to change it with RS232 cable, please scan below setting code firstly, then connect the RS232 cable again.
3 General Configuration 3.1 Inverse color OFF (Default) Only Inverse ON Inverse And Normal Both ON 3.
Illumination OFF 3.3 Good Read Beeper ON (Default) OFF 3.4 Good Read Beeper Volume Low Middle High (Default) 3.
Short 3.6 Good Read Beeper Tone Low Frequency Medium Frequency (Default) Medium High Frequency High Frequency 3.
Delay 750 MS Delay 1000 MS 4 Data Formatting 4.
Add LF Add CRLF Add TAB 4.
Not Save To set a customer prefix, scan the Set Custom Prefix barcode and the numeric barcodes which representing the hexadecimal values of a desired prefix, and then scan the Save barcode. Refer to Appendix 2: ASCII Table for hexadecimal values of characters. Example: Set the custom Prefix to “ODE” 1. Check the hex values of “ODE” in the ASCII Table. (“ODE”: 4F, 44, 45) 2. Scan the Set Custom Prefix barcode. 3. Scan the numeric barcodes”9”,”9”,“4”,“F”,“4”,“4”,“4”and“5”in Appendix 3 . 4.
4.3 Add Suffix Set Custom Suffix Save Not Save To set a customer suffix, scan the Set Custom Suffix barcode and the numeric barcodes which representing the hexadecimal values of a desired suffix, and then scan the Save barcode. Refer to Appendix 2: ASCII Table for hexadecimal values of characters. Example: Set the custom Suffix to “ODE” 1. Check the hex values of “ODE” in the ASCII Table. (“ODE”: 4F, 44, 45) 2. Scan the Set Custom Suffix barcode.
5 Symbologies 5.1 General Setting 5.1.1 Restore Symbology Default Setting Symbologies Enable: Code 128, Code 39, UPC, EAN, Interleaved 2 of 5, Code 93, Coda Bar, GS1-128, Data Matrix, PDF417, QR, Maxi Code, Aztec. Restore Symbology Default 5.1.2 Optimize Performance for Retail Use Case Make for optimize scan performance in most retail barcode scan use case. Symbologies Enable: UPC, EAN, Code128, QR, PDF417. Only Enable Retail Barcode 5.1.
5.2 1D Symbologies 5.2.1 Code 128 Enable/Disable Code 128 Enable Code 128 (Default) Disable Code 128 Message Length Message length can be set to the maximum value or minimum value. The value between the maximum and the minimum is valid. The maximum value and minimum value can be set using “Programming Command”. Please check the programming command guide for the detail. Code 128 max length command: 020A03. The parameter of this command can be set from min to 90. Code 128 min length command: 020A02.
5.2.2 EAN-8 Enable/Disable EAN-8 Enable EAN-8 (Default) Disable EAN-8 Transmit Check Digit EAN-8 is 8 digits in length with the last one as its check digit used to verify the accuracy of the data. Transmit EAN-8 Check Digit (Default) Do Not Transmit EAN-8 Check Digit Add-On Code An EAN-8 barcode can be augmented with a two-digit or five-digit add-on code to form a new one.
Disable 2-Digit Add-On Code (Default) Enable 5-Digit Add-On Code Disable 5-Digit Add-On Code (Default) Add-On Code Required EAN-8 Add-On Code Required EAN-8 Add-On Code Not Required (Default) ENA/JAN-8 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space.
5.2.
Add-On Code Required EAN-13 Add-On Code Required EAN-13 Add-On Code Not Required (Default) ENA/JAN-13 Addenda Separator When this feature is enabled, there is a space between barcode and addenda. When this feature is disabled, there is no space. Enable ENA/JAN-13 Addenda Separator (Default) Disable ENA/JAN-13 Addenda Separator ISBN Translate When enable this feature and is scanned, ENA-13 Book land symbols are translated into their equivalent ISBN number format.
5.2.
UPC-E0 Expand UPC-E0 expand expands the UPC-E code to the 12 digits, UPC-A format. Enable UPC-E0 Expand Disable UPC-E0 Expand (Default) UPC-E0 Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda.
UPC-E0 Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted.
5.2.5 UPC-A Enable/Disable UPC-A Enable UPC-A (Default) Disable UPC-A UPC-A Check Digit Enable UPC-A Check Digit (Default) Disable UPC-A Check Digit UPC-A Addenda Required When required is scanned, the scanner will only read UPC-E barcodes that have addenda.
UPC-A Addenda Separator Enable UPC-A Separator (Default) Disable UPC-A Separator UPC-A: Number System The number system digit of UPC symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will be not transmitted.
UPC-A: Addenda Enable 2 Digit Addenda Disable 2 Digit Addenda (Default) Enable 5 Digit Addenda Disable 5 Digit (Default) 30
5.2.6 Interleaved 2 Of 5 Enable/Disable Interleaved 2 Of 5 Enable Interleaved 2 Of 5 (Default) Disable Interleaved 2 Of 5 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming Command. Please check the programming command guide for the detail. Interleaved 2 of 5 max length command: 020404. The parameter of this command can be set from min to 80.
5.2.7 Matrix 2 Of 5 Enable/Disable Matrix 2 Of 5 Enable Matrix 2 Of 5 Disable Matrix 2 Of 5 (Default) Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Matrix 2 of 5 max length command: 020803. The parameter of this command can be set from min to 80. Matrix 2 of 5 min length command: 020802.
5.2.8 Industrial 2 Of 5 Enable/Disable Industrial 2 Of 5 Enable Industrial 2 Of 5 Disable Industrial 2 Of 5 (Default) Message Length Message length can be set to the maximum value, minimum value. The value is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Industrial 2 of 5 max length command: 020603. The parameter of this command can be set from min to 48.
5.2.
Code 39 Append This function allows the scanner to append several Code 39 barcode data together before transmitting to host. When the scanner encounters a Code 39 barcode with append character (ex. Space character), it buffers the data until it reads a Code 39 barcode which does not have append character. Then the data is transmitted in the order that the barcodes were read.
5.2.10 Coda Bar Enable/Disable Coda Bar Enable Coda Bar (Default) Disable Coda Bar Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Coda bar max length command: 020206. The parameter of this command can be set from min to 60. Coda bar min length command: 020205.
Transmit Start/Stop Character Transmit Start/Stop Character Do Not Transmit Start/Stop Character (Default) Coda bar Check Character No Check Char (Default) Validate And Transmit Validate No Transmit 37
5.2.11 Code 93 Enable/Disable Code 93 Enable Code 93 (Default) Disable Code 93 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Code 93 max length command: 020D03. The parameter of this command can be set from min to 80. Code 93 min length command: 020D02.
5.2.12 GS1-128 Enable/Disable GS1-128 Enable GS1-128 (Default) Disable GS1-128 Message Length Message length can be set to the maximum value, minimum value. The data between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. GS1-128 max length command: 020B03. The parameter of this command can be set from min to 80. GS1-128 min length command: 020B02.
5.2.13 MSI Enable/Disable MSI Enable MSI Disable MSI (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. MSI max length command: 020E04. The parameter of this command can be set from min to 48. MSI min length command: 020E03. The parameter of this command can be set from 4 to max.
MSI Check Character Validate Type10 Transmit Validate 2 Type10 No Transmit (Default) Validate Type10 Then Type11 Char NO Transmit Validate Type10 Then Type11 Char Transmit Validate 2 Type10 Char Transmit Validate 2 Type10 Char No Transmit Disable MSI Check 41
5.2.
5.3 2D Symbologies 5.3.1 PDF 417 Enable/Disable PDF 417 Enable PDF 417 (Default) Disable PDF 417 Enable/Disable Micro PDF 417 Enable Micro PDF 417 Disable Micro PDF 417 (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. PDF417 max length command: 021F06.
5.3.2 QR Code Enable/Disable QR Code Enable QR Code (Default) Disable QR Code Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum is valid. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. QR max length command: 023703. The parameter of this command can be set from min to 7089. QR min length command: 023702.
5.3.3 Data Matrix Enable/Disable Data Matrix Enable Data Matrix (Default) Disable Data Matrix Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Data Matrix max length command: 023603. The parameter of this command can be set from min to 3116. Data Matrix min length command: 023602.
5.3.4 Maxi code Enable/Disable Maxi code Enable Maxi Code Disable Maxi Code (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Maxi Code max length command: 023403. The parameter of this command can be set from min to 150. Maxi Code min length command: 023402.
5.3.5 Aztec Enable/Disable Aztec Enable Aztec (Default) Disable Aztec Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Aztec max length command: 023306. The parameter of this command can be set from min to 3832. Aztec min length command: 023305.
5.3.6 Hanxin Enable/Disable Hanxin Enable Hanxin Disable Hanxin (Default) Message Length Message length can be set to the maximum value, minimum value. The data is valid between the maximum and the minimum. The maximum value and minimum value can be set using Programming command. Please check the programming command guide for the detail. Hanxin max length command: 023803. The parameter of this command can be set from min to 7833. Hanxin min length command: 023802.
5.4 Postal Symbologies 5.4.1 China Postal Code Enable/Disable China Postal Code Enable China Postal Code Disable China Postal Code (Default) 5.4.
6 Q&A 6.1 How to scan Japanese in QR codes? Application environment QR coding rule UTF8\GB2312 Shift-JIS word documents Excel or notepad system languages:JP Sample Code こんにちは 123 あいうえ ABC かきくけこ 456 50
6.
6.3 How to scan Thai in QR codes? Application environment QR coding rule UTF8 CP874 แบบทดสอบภาษาไทยบารโคด 12345678 ห ฟ ด ดาสกหฟรา แสส KTB CO.
7 Appendix 7.
Matrix 2 of 5 ISBN ISSN PDF417 Data Matrix ]X0 ]X1 ]X2 ]X3 ]X4 ]X5 ]L0 ]d0 ]d1 ]d2 ]d3 ]d4 ]d5 ]d6 ]Q0 ]Q1 ]Q2 ]Q3 QR Code ]Q4 ]Q5 ]Q6 Specified by the manufacturer No parity check One check digit, MOD10; transmit check digit One check digit, MOD11; do not transmit check digit Standard ISBN Standard ISSN Comply with 1994 PDF417 specifications ECC000 - ECC140 ECC200 ECC200, FNC1 is the 1st or 5th character after the start character ECC200, FNC1 is the 2nd or 6th character after the start character ECC20
7.2 Appendix 2: ASCII Table Hex Dec Char 00 01 02 03 04 05 06 07 08 09 0a 0b 0c 0d 0e 0f 10 11 12 13 14 15 16 17 18 19 1a 1b 1c 1d 1e 1f 20 21 Hex 22 23 24 25 26 27 28 29 2a 2b 2c 2d 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Dec 34 35 36 37 38 39 40 41 42 43 44 45 NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SP ! Char " # $ % & ` ( ) * + , - (Null char.
2e 2f 30 31 32 33 34 35 36 37 38 39 3a 3b 3c 3d 3e 3f 40 41 42 43 44 45 Hex 46 47 48 49 4a 4b 4c 4d 4e 4f 50 51 52 53 54 55 56 57 58 59 5a 5b 5c 5d 5e 5f 60 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 Dec 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C D E Char F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _ ' (Dot) (Forward Slash) (Colon) (Semi-colon) (Less Than) (Equal Sign) (Greater Than) (Que
61 62 63 64 65 66 67 68 69 Hex 6a 6b 6c 6d 6e 6f 70 71 72 73 74 75 76 77 78 79 7a 7b 7c 7d 7e 7f 97 98 99 100 101 102 103 104 105 Dec 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 a b c d e f g h i Char j k l m n o p q r s t u v w x y z { | } ~ DEL (Left/ Opening Brace) (Vertical Bar) (Right/Closing Brace) (Tilde) (Delete) 7.
4 5 6 7 8 9 A B C D E F 58