Enter Setup
Turn On Aimer
You may turn on the aimer on the engine for a certain period of time with a command sent from the host. When using this
feature, you should first query the range of possible values for the setting. Note that the engine cannot scan barcodes when it is
executing this command.
LEDONAyy (yy: Specify the length of time the aimer stays on, 10-3,600,000ms)
Command for querying whether the engine supports this feature: LEDONA* or LEDONA&
Returning LEDONA<ACK> indicates the engine supports this feature.
Command for querying the range of possible values for the setting: LEDONA^
Returning LEDONA10-3600000 <ACK> indicates the range for the length of time the aimer stays on is 10-3,600,000ms.
Example: Turn on the aimer for 2,000ms
Enter: ~<SOH>0000#LEDONA2000;<ETX>
Response: <STX><SOH>0000#LEDONA2000<ACK>;<ETX>
Surround GS1 Application Identifiers (AI’s) with Parentheses
When Surround GS1 AI’s with Parentheses is selected, each application identifier (AI) contained in scanned data will be
enclosed in parentheses in the output message.
** Do Not Surround GS1 AI’s with Parentheses
Surround GS1 AI’s with Parentheses
** Exit Setup