Information

Enter Setup
Modify Stop Scanning Command
The Stop Scanning command can consist of 1-10 characters (HEX values from 0x01 to 0xFF). In this command, the character
“?” (HEX: 0x3F) cannot be the first character. The default Stop Scanning command is <SOH> P <EOT>.
Modify Stop Scanning Command
Set the Stop Scanning command to “*P”:
1. Scan the Enter Setup barcode.
2. Scan the Modify Stop Scanning Command barcode.
3. Scan the numeric barcodes “2”, “A”, “5” and “0 from the “Digit Barcodes” section in Appendix.
4. Scan the Save barcode from the “Save/Cancel Barcodes” section in Appendix.
5. Scan the Exit Setup barcode.
Make a Beeping Sound
You may wish to force the engine to beep upon a command sent from the host. A beeping sound is made to gain a user’s
attention to an error or other important event.
BEEPONxxxFyyyTnnV (xxx: The desired frequency, 1-20,000Hz; yyy: The desired duration, 1-10,000ms; nn: The desired
volume level, 1-20 (lowest-loudest))
Example: Make a 50ms beep at 2,000Hz with volume level set to 20
Enter: ~<SOH>0000#BEEPON2000F50T20V;<ETX>
Response: <STX><SOH>0000#BEEPON2000F50T20V<ACK>;<ETX>
** Exit Setup
35