Instructions

QU-CD-720M/820M Manual Ver3.19
4
1
)
Pre-reading dispense mode
If the DIP1 is set to β€œON”, when get a payout signal,the card will be carried into the
Reading-place from the Ready-place; When get another payout signal again, the card will be
carried into the Taken-place from the Reading-place.
2
)
Direct dispense mode
If the DIP1 is set to β€œOFF”, DIP2 = OFF, when get a payout signal,the card will be carried
into the Taken-place from the Ready-place.
3
.4 Input and Output Circuit
Output Circuit
Input Circuit
All output signal is open-collector
All input signal is TTL. The max
input voltage is 5V and input level to be
output and the maximum output is
3
0V/100mA. Output signal keep 200ms at
2
00ms minimum.
least.
The card is the
Reading-place.
The card is the
Taken-place.
The card is the
Ready-place.