Instructions
NFC &
MIFARE & ISO14443AB & ISO15693 & ISO18000 & ISO7816 IC Card Module www.quio-rfid.de
Copyright © 2003-2022 Quick Ohm Küpper & Co. GmbH. All rights reserved. 29/101
BIT4:BIT3 = 0:0 JCP04
BIT4:BIT3 = 0:1 JCP05
BIT4:BIT3 = 1:0 JCP02
BIT4:BIT3 = 1:1 JCP03
Process ISO15693: BIT5 = 0: ON; BIT5 = 1: OFF
Process ISO14443 TYPE A: BIT6 = 0: ON; BIT6 = 1: OFF
RFU: BIT7 = 1(MUST BE 1);
Success:
Frame 0x1E Checksum
Failure:
Frame 0xE1 Checksum
Example:
Send: 0x00 05 00 1E 00 1B
Return: 0x00 04 01 1E 1B
5.2.20 Set the RF Output Level
Function: To set the RF output level. When the RF output power is reduced, the card
operation distance will be reduced too. The customer could set it according to the concrete needs.
Settings will save in the module; it will be not lost after power OFF. This command does not
support in CL RC663 devices.
Host sends:
Frame 0x02 Power Checksum
Power: 1 byte, 0x00: the strongest; 0x01: the stronger; 0x02: the weak; 0x03: the weakest;
other values: RFU.
Success:
Frame 0x02 Checksum
Failure:
Frame 0xFD Checksum
Example:
Send: 0x00 05 00 02 00 07
Return: 0x00 04 01 02 07
5.2.21 Module Contactless Protocol Set
Function: The default for setting module contactless protocol is ISO14443A. If the module
doesn't support ISO14443A, the default protocol is ISO15693. The setting won't be saved and
will return to the default status at next power on. The firmware version 6.00 or later was build in
automatic protocol set function.
Host sends:
Frame 0x70 Mode Checksum
Mode: 1 byte, 0: ISO14443A; 1: ISO14443B; 2: ISO15693; 3: I.CODE 1; 4:
ISO18000-3M3; other value: RFU