Instructions

13.56 MHz Modbus-RTU RFID Reader QU-950-4-HF User Manual
Quick Ohm Küpper & Co. GmbH
QUIO
®
18
if LSB Selected in Parameter register, the Block Data value is as
below:
Register
address
158
70
40016
Data1
Data0
40017
Data3
Data2
40018
Data5
Data4
40045
Data59
Data58
40046
Data61
Data60
40047
Data63
Data62
if MSB Selected in Parameter register, the Block Data value is as
below:
Register
address
158
70
40016
Data0
Data1
40017
Data2
Data3
40018
Data4
Data5
40045
Data58
Data59
40046
Data60
Data61
40047
Data62
Data63
6.2.9 Reseved Register:4004840099
These registers are not used.