Instructions

13.56 MHz Modbus-RTU RFID Reader QU-950-4-HF User Manual
Quick Ohm Küpper & Co. GmbH
QUIO
®
13
6.1.6 Key Register 2:40103~40105
Default value:0xFFFF0xFFFF , 0xFFFF
if LSB Selected in Parameter register, the key value is as below:
Register
158
70
Address
40103
Key1
(default 0xFF
Key0
default 0xFF
40104
Key3
default 0xFF
Key2
default 0xFF
40105
Key5
default 0xFF
Key4
default 0xFF
if MSB Selected in Parameter register, the key value is as below:
Register
158
70
Address
40103
Key0
(default 0xFF
Key1
default 0xFF
40104
Key2
default 0xFF
Key3
default 0xFF
40105
Key4
default 0xFF
Key5
default 0xFF
6.1.7 Delay Time Register For Same Card:40106
The register is used to request the last time if the card serial number has been
cleared and within the time set by the register. Read the card, think no card into. If
this time is exceeded, it can be re-read as a new tag Operation. This function is mainly
used to prevent users from inadvertently operating and Misreading many times.
Default value:0x0000
unit:100ms