Product guide

5-7 P/N 480-0062-00-10
Chapter 5: Advanced Topic: Diagnostics/Maintenance
Display Active Alarms
You are able to display all active alarms as follows:
1. Through CLI, access the Monitor prompt.
2. Type alarm a. The active alarms will be listed. See section Valid Alarms for field definitions. If
you enter alarm without a command following it, both active alarms and the alarm history will
be displayed.
Figure 5-2 Active Alarm Sample
Display Alarm History
1. Through CLI, access the Monitor prompt.
2. Type alarm h. An alarm history will be displayed. See section Valid Alarms for field definitions.
If you enter alarm without a command following it, both active alarms and the alarm history will
be displayed.
Figure 5-3 Alarm History Sample
IP# Sequence#Type#Severity# Desc# Slot# Device#Analog Interface# Channel# Date/Time
192.166.28.230:944:ALR:3:Border Element connection lost:0:0:0:0:TUE OCT 14 14:05:27 2003
IP# Sequence#Type#Severity# Desc# Slot# Device# Analog Interface# Channel# Date/Time
192.166.28.230:944:ALR:3:Border Element connection lost:0:0:0:0:TUE OCT 14 14:05:27 2003
192.166.28.230:945:RPT:4:Gatekeeper status (Gatekeeper(192.168.20.175) removed):0:0:0:0:TUE O
C
14 14:05:27 2003
192.168.20.175:946:RPT:4:Gatekeeper status (Gatekeeper(0.0.0.0) removed):0:0:0:0:TUE OCT 14