8.4 POSITION OF THE DATA PLATE FOR DRYER
FIG.
8
9.0 COMPRESSOR ROOM
9.1 FLOOR
The floor must be even and of industrial type; the total weight of the machine is shown in the Chap. 13.0
Remember the total weight of the machine when positioning it.
9.2 VENTILATION
When the machine is operating, the room temperature must not be higher than 46 °C (114,8 °F) or lower than 2 °C (35,6 °F).
The volume of the room must be about 60 m
3
The room must be provided with 2 openings for ventilation with a surface area of about 0,5 m
2
each. The first opening must be in a high position to evacuate the hot air, the second opening must be low to allow the intake of external air
for ventilation. If the environment is dusty it is advisable to extract fit a filtering panel on this opening.
9.3 EXAMPLES OF VENTILATION OF THE COMPRESSOR ROOM
FIG. 9
ATTENTION: Removable
pipe to allow cleaning of the
radiator.
Hot air pipe
Fan air
output
10.0 TRANSPORT AND HANDLING
The machine must be transported as shown in the following figures.
FIG.
10
11.0 UNPACKING
After removing the packing, ensure that the machine is unbroken and that there are no visibly damaged parts.
If you are in doubt, do not use the machine but contact the manufacturer or to your dealer. The packing material (plastic bags) must not be
left within the reach of children or abandoned in the environment, as they are a potential source of danger and pollution. Dispose of these
materials in the approved collection centres.