Product Manual
Cod. 9828093011 00 - Edition 03/2015 - 47
ENGLISH
21.0 GENERAL ORDINARY MAINTENANCE REQUIRES TRAINED PERSONNEL
BEFORE CARRYING OUT ANY MAINTENANCE IT IS MANDATORY TO STOP THE MACHINE AND DISCONNECT IT FROM
THE POWER MAINS.
MAINTENANCE SCHEDULE
These maintenance intervals are recommended for work environments that are not dusty and are will ventilated. For particularly dusty
environments, double the frequency of controls.
Every Day (after use)
Check automatic condensation drain (dryer)
Every 50 working hours
Drain condensate from the oil tank
Check the oil level
Clean the filter of the automatic condensate drain (dryer)
Every 500 hours
Replace oil (at first 500 hrs)
Replace oil filter (at first 500 hrs)
Tighten the screws fixing the electric cables (at first 500 hrs)
Clean the air inlet filter
Clean the condenser heat exchanger (unit with dryer)
Clean the inlet filtration panels
Every 2000 hours
Replace the inlet air filter
Replace the oil
Replace the oil filter
Retighten all power cable connections
Safety temperature test
Maintenance kit of the automatic condensate drain (dryer)
Every 4000 hours
Clean the finned surface of the air-oil cooler
Replace the oil separator filter
Every 8000 hours
Intake valve service kit
Check status of oil return valve and oil pipes
MPV Service kit
Every 24000 hours
Air-end overhaul kit
N.B.: THE OPERATIONS MARKED ARE DESCRIBED IN PART "A" OF THIS MANUAL ON CHAPTER 15.2