19.0 TROUBLE-SHOOTING AND EMERGENCY REMEDIES
N.B. OPERATIONS MARKED MUST BE PERFORMED BY PROFESSIONALLY SKILLED PERSONNEL APPROVED THE
MANUFACTURER.
ALL WORK MUST BE PERFORMED BY PROFESSIONALLY SKILLED PERSONNEL. BEFORE CARRYING OUT ANY
MAINTENANCE JOBS IT IS MANDATORY TO STOP THE MACHINE AND DISCONNECT IT FROM THE POWER MAINS.
19.1 TROUBLE-SHOOTING AND EMERGENCY REMEDIES FOR SCREW COMPRESSOR (Standard controller for fixed speed
compressor)
F
A
ULT FOUND POSSIBLE
CAUSES
OBSERV
A
TIONS
1) The machine does not start 1A - no
power
1B - the transformer protection device has
tripped
-
check
the power supply line,
Chapter 12.2
- replace fuses
2) The machine does not start
the pilot lamp (Ref. 8 Fig. 15) is flashes.
The pictograph appears intermittently
(Ref. 7 Tab. B)
2A - Phases
incorrect
2B - the main motor protection device has
tripped
2C – Temperature switch on element oulet
has
tripped
-
Verify
phase sequence
- to check possible motor failure
-environment temperature too high;
improve ventilation in the compressor
room, Chapter 9.2
- cooling radiator is dirty, clean the
radiator
- oil level too low; top up the oil tank
3) The machine does not start
the pilot lamp (Ref. 8 Fig. 15) is flashes.
The pictograph appears intermittently
(Ref. 5 Tab. B)
3A - The
oil
high
temperature
protection
has
tripped
-
environment temperature too
high;
improve ventilation in the compressor
room, Chapter 9.2
- cooling radiator is dirty, clean the
radiator
- oil level too low; top up the oil tank
4) The compressor does not reach working
pressure
4A - the compressed air consumption is
too high
4B - the discharge electrovalve remains
closed.
- check the electric system
5) Excess oil consumption
5A - deteriorated
oil
separating
f
ilter
oil level is too high
-
change the oil separating
f
ilter,
Chapter 23
19.2 - TROUBLE-SHOOTING AND EMERGENCY REMEDIES FOR SCREW COMPRESSOR (Graphic controller for fixed speed
compressor)
F
A
ULT FOUND POSSIBLE
CAUSES
OBSERV
A
TIONS
1) The machine does not start 1A - no
power
1B - the transformer protection device has
tripped
-
check
the power supply line,
Chapter 12.2
- replace fuses
2) The machine does not start
the pilot lamp (Ref. 5 Fig.16) is flashes.
The pictograph appears intermittently
(Status icons Shutdown)
2A - Phases
incorrect
2B - the main motor protection device has
tripped
2C – Temperature switch on element oulet
has tripped
-
Verify
phases sequence
- to check possible motor failure
-environment temperature too high;
improve ventilation in the compressor
room, Chapter 9.2
- cooling radiator is dirty, clean
the
radiator
- oil level too low; top up the oil tank
3) The machine does not start
the pilot lamp (Ref. 5 Fig.16) is flashes.
The pictograph appears intermittently
(Status icons Shutdown)
3A - The
oil
high
temperature
protection
has
tripped
-
environment temperature too
high;
improve ventilation in the compressor
room, Chapter 9.2
- cooling radiator is dirty, clean the
radiator
- oil level too low; top up the oil tank
4) The compressor does not reach working
pressure
4A - the
compressed
air
consumption
is
too high
4B - the discharge electrovalve remains
closed.
- check the electric system
5) Excess oil consumption 5A - deteriorated
oil
separating
f
ilter
oil level is too high
-
change the oil separating
f
ilter,
Chapter 23