Product Manual
Cod. 9828093011 00 - Edition 03/2015 - 37
ENGLISH
BEFORE PERFORMING ANY MAINTENANCE IT IS MANDATORY TO STOP THE MACHINE AND DISCONNECT IT FROM
THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.
15.5 CLEANING THE INLET PANEL FILTER
- Switch off the machine with pushbutton Ref. 1 Fig. 17: in this way the machine stops after idle time running.
- Turn on the main supply switch, Ref. 3 (on the screw-compressor) and Ref. 3A (on the dryer if fitted) Fig. 17.
- Remove the filters covers from cabinet door Ref. 1 Fig. 18.
- Clean the filters pads covers using compressed air or water. Do not use solvents.
- Once operation is complete, reassemble the filter covers Ref. 1 Fig. 18.
FIG.
18
1
1