15.0 ORDINARY MAINTENANCE TO BE DONE BY THE USER
BEFORE PERFORMING ANY MAINTENANCE IT IS MANDATORY TO STOP THE MACHINE AND DISCONNECT IT FROM
THE POWER MAINS AND FROM THE COMPRESSED AIR DISTRIBUTION NETWORK.
The maintenance jobs described in this chapter may be carried out by the user.
The more complex maintenance jobs which require professionally skilled personnel are listed in the chaper on GENERAL ROUTINE
MAINTENANCE. (See Chap. 21.0)
15.1 GENERAL INFORMATION
15.2 MAINTENANCE PROGRAMME
OPERATIONS THAT MAY BE CARRIED OUT BY THE USER
 OPERATIONS THAT REQUIRE SKILLED PERSONNEL; THESE OPERATIONS ARE ILLUSTRATED IN PART B OF THIS
MANUAL.
These maintenance intervals are recommended for work environments that are not dusty and are will ventilated. For particularly dusty
environments, double the frequency of controls.
Every Day (after use)
Check automatic condensation drain (dryer)
Every 50 working hours
Drain condensate from the oil tank
Check the oil level
Clean the filter of the automatic condensate drain (dryer)
Every 500 hours
Replace oil filter (at first 500 hrs)
Tighten the screws fixing the electric cables (at first 500 hrs)
Clean the air inlet filter
Clean the condenser heat exchanger (unit with dryer)
Clean the inlet filtration panels
Every 2000 hours
Replace the inlet air filter
Replace the oil filter
Retighten all power cable connections
Safety temperature test
Maintenance kit of the automatic condensate drain (dryer)
Oil Fluid sample
Every 4000 hours
 Clean the finned surface of the air-oil cooler
Replace the oil separator filter
Every 8000 hours
Intake service kit
Check status of oil return valve and oil pipes
MPV Service kit
Replace the oil *
*ThecompressormustbemaintainedwithQuinSynPlus(8,000hourmaximum),QuinSynXP(12,000hour
maximum)orQuinSynFfoodgrade(6,000hourmaximum).Maximumfluidchangeintervalsarenotedperfluid.
Actualfluidchangeintervalistobedeterminedbyfluidsamplingreport,nottoexceedmaximumfluid
change
interval.Fluidsamplesmustbetakenevery2,000hoursorasdirectedbytheanalysisreport.For lightusage
units,afluidsamplemustbetakenaminimum,ofeverysix(6)months,beginningatstartup.