Product Manual
34
Edition 03/2015 Cod. 9828093011
00-
ENGLISH
Terminology
Term
Explanation
ARAVF
Automatic restart after voltage failure.
Power recovery time
Is the period within which
the
voltage
must
be
restored
to
have
an
automatic
restart. Is accessible i
f
the
automatic
restart is activated. To activate the automatic restart function, consult your supplier.
Restart delay This parameter allows to
programme
that
not
all
compressors
are
restarted
at
the
same time after a power
failure
(ARAVF active).
Compressor element outlet
The regulator does not accept
inconsistent
settings,
e.g.
i
f
the
warning
level
is
programmed
at 95 ˚C (203 ˚F), the minimum limit for the shut-down level changes to 96 ˚C (204 ˚F). The
recommended difference between the warning level and shut-down level is 10 ˚C (18 ˚F).
Delay at shut- down signal
Is the time for which the signal
must
exist
before
the
compressor
is
shut
down.
I
f
it is required to program
this
setting to another value, consult your supplier.
Minimum stop time
Once the compressor has
automatically
stopped,
it
will
remain
stopped
for
the
minimum stop time, whatever
happens with the net air pressure. Consult your supplier if a setting lower than 20 seconds is required.
Unloading/ Loading
pressure
The regulator does not accept
illogical
settings,
e.g.
i
f
the
unloading
pressure
is
programmed at 7.0 bar(e)
(101
psi(g)), the maximum limit for the loading pressure changes to 6.9 bar(e) (100 psi(g)). The recommended
minimum pressure difference between loading and unloading is 0.6 bar (9 psi(g)).