Product Manual

20
Edition 03/2015 Cod. 9828093011
00-
ENGLISH
Example
The screen shows the screen number <d.1>, the unit used <hrs> and the related symbol for running hours. Press Enter key (5) to call up the actual
running hours.
Overview of the screens
Digital input screens
Designation Related topic
<d.in> Digital input status
< d.1> Running hours (hrs orx 1000 hrs)
<d.2> Motor starts (x1 orx 1000)
<d.3> Module hours (hrs orx 1000 hrs)
<d.4> Loading hours (hrs or x1 000 hrs)
<d.5> Load relay (x1 or x 1000)
<d.6> Service timer reading (hrs or x 1000 hrs)
<d.7> Actual program version
Parameter screens
Designation Related topic
<P.1>
Selection between local, remote or LAN control
<P.2>
Setting a node ID
for LAN
control and the channels for Mk 4
and Mk 5
<P.3> Settings for IP, gateway and Subnet mask
<P.4>
Pressure band settings
<P.5> Setting a pressure band selection
<P.6> Modifying a service timer
<P.7> Setting of unit
for
temperature
<P.8> Setting of unit for pressure
<P.9>
S
election fo
r
function:
A
utomatic
r
esta
r
t afte
r
voltage failure
<P.10>
<P.11>
Setting of load delay time
<P.12>
Setting of minimum stop time
<P.13>
Setting a password
<P.14>
Remote pressure sensing
Parameter screens
Designation Related topic
<Pr.2>
Protections screens
Test screens
Designation Related topic
<t.1> Display test
<t.2> Safety valve test