PRODUCT USE
Typical applications for QUIKRETE
®
Non-Shrink Precision Grout
include grouting of:
• All types of machinery
• Steel columns
• Bearing plates
• Precast concrete
• Other anchoring conditions that require high in-service
strength
The non-shrink characteristics of Non-Shrink Precision Grout make it
stable and capable of handling high load transfers.
SIZES
• QUIKRETE
®
Non-Shrink Precision Grout – 50 LB (22.7 kg) bags
YIELD
• Each 50 lb (22.7 kg) bag of QUIKRETE
®
Non-Shrink Precision
Grout will yield 0.45 cu ft (12.7 L) at flowable consistency.
TECHNICAL DATA
APPLICABLE STANDARDS
ASTM International
• ASTM C109/C109M Standard Test Method for Compressive
Strength of Hydraulic Cement Mortars (Using 2-in. or [50-mm] Cube
Specimens)
• ASTM C827 Standard Test Method for Change in Height at Early
Ages of Cylindrical Specimens of Cementitious Mixtures
• ASTM C939 Standard Test Method for Flow of Grout for Preplaced-
Aggregate Concrete (Flow Cone Method)
• ASTM C1090 Standard Test Method for Measuring Changes in
Height of Cylindrical Specimens from Hydraulic-Cement Grout
• ASTM C1107 Standard Specification for Packaged Dry, Hydraulic-
Cement Grout (Nonshrink)
• ASTM C1107 Standard Test Method for Flow of Hydraulic Cement
Mortar
• ASTM E488 Standard Test Methods for Strength of Anchors in
Concrete and Masonry Elements
U.S. Army Corps of Engineers (USACE) - CRD 621
PHYSICAL/CHEMICAL PROPERTIES
QUIKRETE
®
Non-Shrink Precision Grout complies with all properties
of ASTM C1107 and CRD 621 producing the results shown in Table
1.
TABLE 1 TYPICAL PHYSICAL PROPERTIES
AT 73°F (23°C)
Compressive strength, ASTM C109 modified per ASTM C1107
Plastic consistency
1 day 3000 psi (20.7 MPa)
3 days 9500 psi (65.5 MPa)
7 days 10,000 psi (68.9 MPa)
28 days 14,000 psi (96.5 MPa)
Height change, ASTM C1090
1, 3, 7 and 28 days 0 - 0.2%
Height change, ASTM C827 + 0.6%
Flowable consistency
1 day 3000 psi (20.7 MPa)
3 days 9000 psi (62.1 MPa)
7 days 9500 psi (65.5 MPa)
28 days 12,500 psi (86.2 MPa)
Height change, ASTM C1090
1, 3, 7 and 28 days 0 - 0.2%
Height change, ASTM C827 + 0.4%
Fluid consistency
1 day 2500 psi (17.2 MPa)
3 days 5000 psi (34.5 MPa)
7 days 6000 psi (41.4 MPa)
28 days 8000 psi (55.2 MPa)
Height change, ASTM C1090
1, 3, 7 and 28 days 0 - 0.2%
Height change, ASTM C827 + 0.3%
Pull-out strength, ASTM E488
1
35,000 psi (241 MPa)
PRODUCT DESCRIPTION
QUIKRETE
®
Non-Shrink Precision Grout is a high strength, non-metallic, Portland
cement based material with expansive additives designed for grouting all types of
machinery, steel columns, bearing plates, pre-cast concrete, and anchoring
app
li
ca
ti
o
n
s
.
Non-Shrink Grouting
03 62 00
DIVISION 3