Technical Data

• Reducing amount of water will yield a putty-like consistency for
vertical applications
• Pour mixed material into hole or void to slightly above floor level
• Hold bolt or post in place until material begins to stiffen
Note - No special curing is required.
PRECAUTIONS
•Mix only enough QUIKRETE
®
Anchoring Cement - Exterior Use to be
used within 10 minutes
•Some dusting may occur during mixing process. Fresh cement
mixtures may be irritating to skin. Wash skin exposed to fresh cement
with clean water. Consult Material Safety Data Sheet (MSDS). Wear
eye protection and appropriate safety equipment and clothing.
WARRANTY
The QUIKRETE
®
Companies warrant this product to be of
merchantable quality when used or applied in accordance with the
instructions herein. The product is not warranted as suitable for any
purpose or use other than the general purpose for which it is
intended. Liability under this warranty is limited to the replacement of
its product (as purchased) found to be defective, or at the shipping
companies’ option, to refund the purchase price. In the event of a
claim under this warranty, notice must be given to The QUIKRETE
®
Companies in writing. This limited warranty is issued and accepted in
lieu of all other express warranties and expressly excludes liability for
consequential damages.
The QUIKRETE
®
Companies
One Securities Centre
3490 Piedmont Rd., NE, Suite 1300, Atlanta, GA 30305
(404) 634-9100 • Fax: (404) 842-1425
* Refer to www.quikrete.com for the most current technical data,
SDS, and guide specifications
Revised 09-08-2016