Specification
QUIKRETE® Guide Specification
FastSet™ Repair Mortar (No. 1241)
Polymer Modified, Shrinkage Compensated, Rapid Setting Concrete Repair Mortar
Section 030100
Maintenance of Concrete
PART 1 – GENERAL
1.10 SUMMARY
A. Provide repair mortar for vertical overhead or horizontal patch and repair of existing substrate.
B. Related Sections: Other specification sections which relate directly to the work of this section
include the following:
Section 030130: Maintenance of Cast-in-place Concrete
Section 030140: Maintenance of Precast Concrete
Section 033000: Cast-In-Place Concrete
Section 033100: Structural Concrete
Section 034100: Pre-Cast Structural Concrete
1.20 SUBMITTALS
A. Product Data: Submit manufacturer’s product data and installation for each material and product
used. Include manufacturer’s Material Safety Data Sheets.
1.30 REFERENCES
A. ASTM C 109: Compressive Strength of Hydraulic Mortars
B. ASTM C 191: Setting Time of Hydraulic Cement
C. ASTM C 882: Slant Shear Bond Strength
D. ASTM C 928: Rapid Hardening Cementitious Materials for Concrete Repairs
E. Utah D.O.T. Bond/Slant Shear Testing.
1.40 QUALITY ASSURANCE
A. Manufacturer’s Qualifications: The manufacturer shall be a company with at least fifteen years
experience in the manufacturer and marketing of pre-packaged cementitious repair materials.
B. Installer’s Qualifications: The contractor shall be qualified to perform the work specified by reason
of experience.
1.50 DELIVERY, STORAGE AND HANDLING
A. Deliver products in original packaging, labeled with product identification, manufacturer, batch
number and shelf life.