Installation Guide

SECTION 3. Installation
Installation & Owner’s Guide QW-TILE 5
CAUTION:
Make sure that the jobsite is neat and clean before
working with the mats. Nails, screws, and other sharp
debris can damage the mats creating a potential
shock hazard. Any mats which become torn or
otherwise damaged must not be used.
NOTES:
The installation of this heating product shall be in accordance with the manufacturer’s
instructions. Improper installation can result in mats that do not work, poor heating, and can
void the manufacturer’s warranty.
Heating mats should not be installed at or below 32°F (0°C).
Installations over non-insulated concrete subfloors may require a longer period of time to adjust
to your desired temperature.
This equipment shall be installed only by qualified personnel who are familiar with the
construction and operation of the apparatus and the risks involved.
Installation of this product and listed components shall be in accordance with Article 424, of the
National Electrical Code, ANSI/NFPA 70. Listed to UL1693.
CAUTION:
Use copper ONLY as the supply conductor. Type
NM and NMC non-metallic sheathed cable is not
suitable for installing this product.
Preparing the Job Site
1. Ensure the job site is clean before working with the QuietWarmth
®
Peel & Stick Radiant Heat, free of any nails,
screws and other sharp debris that could damage the mats.
2. Tile flooring installations must meet subfloor requirements set forth by the Tile Council of North America (TCNA).