Product specifications
8
Cont
4. Switch Dip Switch # 3 to the ON position.
5. Simultaneously press both the Timer and Anti Freeze buttons on the
controller for 5 seconds
6. The control will now enter the option set up mode, press the Timer button
until the display in the top RH corner of the unit reads C6.
7. Press the Up Temperature key, to change the display from 2n to 3n
8. Press the unit On/Off button to turn off the control
9. Switch Dip Switch # 3 back to the OFF position
10. When the zone control wires are closed the unit will now operate and
provide closed loop heating water at the temperature set on the DSR-100
Anti Freeze & Freeze Protection
For Anti Freeze protection in the Quietside units the following products are
recommended “No Burst”
“Fernox Alphii”
The maximum concentration allowed is 30% by volume which will protect the unit
down to approximately 5 DegF or -11 DegC