Product specifications

67
Specific requirements for installation in Canada
The provinces of Ontario and Alberta have adopted standard ULC S636 requiring
the following additional items to be noted.
1. Maximum flue temperature as tested is 136 DegF, allowing these
units to be vented with Schedule 40 PVC under the regulation of
ULC S636.
2. Under the new requirements of ULC S636 regarding vent
connections to the unit, Quietside requires the Schedule 40 Vent
piping to be secured to the unit using approved PVC cement,
following the cement manufacturers instructions regarding
methodology and curing time. A bead of high temperature silicone
should be also run around the joint to ensure no leaks can occur.
Silicone
seal