Owner`s manual
5
4.1  Connecting the electrical supply 
All QuietCool models require regular 3 prongs, ground with 120 volt power supply. Plug electrical cord into receptacle. If 
using an extension cord be sure it is rated for at least 20 amps for the distance your cord is running. To be safe – make 
sure no other equipment is plugged into the same circuit. The QuietCool should run smoothly on 20 amp, 120 volt, and 60 
Hz circuit. 
4.2 Connecting the water supply 
Connect standard water hose to female fitting on the right side of your QuietCool (looking at the fan blade side). If your 
water pressure is above 60 pounds per square inch (p.s.i) you must use a pressure regulator (which can be found at your 
local hardware store). If you have purchased our optional QR60 gallon reservoir tank – simply attach the garden hose from 
the tank to the cooler. Note: Do not connect to water source exceeding 60 p.s.i. – this can cause damage to your QuietCool. 
5.0 Operating procedures 
Back your QuietCool unit up to a fresh air source 
such as an open door or window so the unit can 
pull in fresh air from the outside. Next, make sure 
you have a natural exhaust at the opposite end of 
the room, bay or building such as a window, door 
or bay door. This will ensure maximum efficiency 
from your unit. Finally make sure there are no 
obstructions between your QuietCool and the 
people / area you need to cool. 
5.1  Filling the units reservoir with water 
Once your water hose is connected – open the water flow valve (located on the front of your unit) only one and a quarter (1 
1/4) turns. This water flow valve adjusts the amount of water to the unit. Next, turn water on and fill the reservoir with water. 
Listen carefully. You can hear water filling the reservoir. Check your water connection – make sure there is no dripping. 
Once the reservoir is filled with water the float valve will automatically shut off the water source. When you no longer hear 
the water running – you know that the float valve is fully 
operational (the water turns off automatically) and you are now ready to turn on the 
water pump. Warning! Do not run water pump without water in the reservoir. 
5.2 Turn-on pump  
To turn-on the water pump - flip the toggle switch for the water pump to on. Switch is 
located on front side of unit. Warning! Do not run water pump without water in the 
reservoir. The water pump will now begin pumping water to the top of the unit so that 
gravity will allow the water to run down the backside of unit inside and on the cooling 
pads. (If the water is dripping off of the pads on to the floor – close the flow valve a 
  QC48” Air Flow Pattern. 
Top: Water control valve 
–
controls water to 
to units water reservoir. Open 1 ¼ turns. 
Bottom: Water hook-up for cleaning and 
flushing water reservoir. 










