Instructions / Assembly
QUIETCOOLSYSTEMS.COM 5
WELCOME
INSTALLATION
WIRING OPERATION
WARRANTY
READ BEFORE ATTEMPTING TO INSTALL AN AFR FAN
GETTING STARTED
NOTE: Always follow local building codes because the fan may require specic fasteners or
anchoring systems not discussed in this installation guide. Installation should be done by a
licensed roong contractor.
IMPORTANT: Do not cut through any rafters or structural members while cutting the fan hole. Only
cut out the roof decking.
GENERAL SAFETY INFORMATION
1. READ INSTRUCTIONS - All safety and operation instructions must be read.
2. RETAIN INSTRUCTIONS - The safety and operating instructions should be kept for future reference.
3. HEED WARNINGS - All warnings should be followed.
4. FOLLOW INSTRUCTIONS - All installation and operating instructions should be followed.
5. WATER - The QuietCool system should not be used near water.
6. HEAT - The QuietCool system should be situated away from heat sources.
7. DAMAGE REQUIRING SERVICE - Only qualied service personnel should service the QuietCool system.
The user should not attempt to service the product.
8. SAFETY PRECAUTIONS -
+ Do not install the fan in wet or windy conditions
+ Tie-off both yourself and your equipment when working on steep pitched roofs to avoid falls
+ Wear safety glasses and protective gloves when using power tools
+ Always wear slip-resistant shoes when working on the roof
+ Do not cut through any rafters or structural members of the roof during installation
TOOLS/MATERIALS YOU WILL NEED
+ Cordless Drill with Nut Driver
+ Roong Nails
+ Reciprocating Saw
+ Measuring Tape
+ Weatherproof Roong Grade Sealant
CHOOSING THE RIGHT LOCATION
Choose a location to install your QuietCool roof mounted fan that allows for balanced airow throughout the attic
space. We always recommend the fan to be installed centrally located on the roof three feet below the ridge line.
This will allow you to access the fan very easily. Your roof mount fan should not be installed any closer than within 5
feet to an existing passive vent, ridge vent, or additional fan unit.
!!
!!
+ Roong Knife
+ Ladder Marker or Carpenter Pencil
+ Optional secondary ashing for tile/cement roofs
+ Optional curb ashing for at roofs
ROOF PITCH REQUIREMENTS (MAX ROOF PITCH 8:12)
AFRs installed with the primary or optional secondary ashing: roofs with 3:12 to 8:12 roof pitch
AFRs installed with the optional curb ashing: roofs with less than 3:12 roof pitch
OPTIONAL ACCESSORIES
+ Secondary Flashing for tile or cement roofs (part number FLA-SEC-3743)
+ Curb Flashing for at roofs (part number FLA-CRB-2222)
IMPORTANT: Installing the AFR without the use of a QuietCool ashing, using an improper ashing
based on the guidelines above, or installing the AFR on roofs with a pitch greater than 8:12 will void
the warranty of the unit and may compromise the integrity of your roof. Only install the AFR using
QuietCool ashings appropriate to the roof in which you are installing the AFR on.
!!