Instructions / Assembly

1-888-QUIETCOOL 18
SMART MODE
Smart Mode will automatically change the speed
based on the attic temperature and humidity.
To activate Smart Mode, simply tap Activate Smart
Mode.
In Smart Mode, the rst parameter that is checked
is the Turn Fan Off humidity level. Regardless of the
temperature in the attic, if the Humidity level in the
attic is above the Turn Fan Off humidity setting, the
fan will not turn on, or if it is already running, the
fan will shut off.
If the humidity in the attic is below the Turn Fan
Off humidity setting, the second parameter
that is checked is the Attic Temperature. If the
temperature inside the attic is within the set
parameters in the app, the fan will turn on at the
appropriate speed.
If the temperature in the attic is below any of the
temperature parameters, the last parameter that
is checked is the Turn Fan On humidity level. If the
humidity level in the attic is above the Turn Fan
On humidity parameter but below the Turn Fan
Off humidity parameter, the fan will turn on at the
Desired Speed.