Instructions / Assembly
1-888-QUIETCOOL 12
Ground the fan to the junction box
using the green ground screw
Specialty Series Fan
Junction
Box
Power Source
14-2 Wire
2 Wire Romex
2 Wire Romex
Thermostat
Figure 3.2B
Low Speed: Tie the red wire from the fan to the taped white wire from the thermostat (see Figure
3.2B)
6. Tie the black wire from the power source to the black wire from the thermostat. Replace the cover
on the junction box.
7. In the thermostat, tie the black wire to one of the black wires from the thermostat. Tie the taped
wire to the other black wire from the thermostat. Using the ground screw in the thermostat, ground
the ground wire from the 2 wire Romex.
8. Tie the two remaining black wires together. Then, tie the remaining copper wires together.
4. SYSTEM OPERATING INSTRUCTIONS
4.1 SETTING THE THERMOSTAT
The thermostat included with your AFR PRO-1.3 is a simple way
to control your attic fan.
The thermostat can be adjusted to any temperature between 60º
and 120º. Whatever temperature you set the thermostat to will
cause your attic fan to turn on when your attic temperature is at
or above the set temperature.
To change the setting of the thermostat, simply take a
screwdriver and twist the dial.
The thermostat also includes a Fire Fuse that will turn off the
attic fan if it detects a temperature above 182ºF in your attic.
The purpose of this is to shut off in the event of a house re to
prevent the spread of ames.