Installation Guide

1-888-QUIETCOOL 16
SMART MODE
Smart Mode will automatically change the speed
based on the attic temperature and humidity.
To activate Smart Mode, simply tap Activate
Smart Mode.
In Smart Mode, the rst parameter that is
checked is the Turn Fan Off humidity level.
Regardless of the temperature in the attic, if the
Humidity level in the attic is above the Turn Fan
Off humidity setting, the fan will not turn on, or if
it is already running, the fan will shut off.
If the humidity in the attic is below the Turn Fan
Off humidity setting, the second parameter
that is checked is the Attic Temperature. If the
temperature inside the attic is within the set
parameters in the app, the fan will turn on at the
appropriate speed.
If the temperature in the attic is below any of the
temperature parameters, the last parameter that
is checked is the Turn Fan On humidity level. If
the humidity level in the attic is above the Turn
Fan On humidity parameter but below the Turn
Fan Off humidity parameter, the fan will turn on
at the Desired Speed.