Technical Specifications
HEATING PANELS
Calorique’s Warm Floors System is available in three standard widths
and two standard voltages. Match the joist spacing and voltage avail-
able to the appropriate heating panel(s) in the following table:
Joist Spacing Watts / Panel 120 Volts AC 240 Volts AC
12 inch / 300 mm 8 FLR13P8W120V FLR13P8W240V
max. length: 45 panels 90 panels
16 inch / 400 mm 10 FLR17P10W120V FLR17P10W240V
max. length: 36 panels 72 panels
24 inch / 600 mm 17 FLR25P17W120V FLR25P17W240V
max. length: 21 panels 42 panels
The maximum length for a particular model means the maximum con-
tinuous length of heating panels for any one run, or panel set. This
length is governed by the maximum amperage that the bus bars are
designed to carry.
The total number of panels used in a single circuit is limited to 16
amps. Use the following table as a quick reference when specifying
only single voltage/width heating panels. When specifying multiple
width heating panels for the same area, make sure that the total
power (watts / panel times the number of sections for all product
types) is less than or equal to the maximum total power figure.
Voltage Maximum Maximum Total Panels
Total Power 12 inch 16 inch 24 inch
120 1920 watts 240 192 112
240 3840 watts 480 349 225
NOTE
If a particular room or area includes more than one joist spacing (e.g.
some joists spaced at 12 inches and some spaced at 16 inches), you
must use the appropriate heating panel for each joist spacing.