Technical Specifications

Floor Heating Panels and Ceiling Heating Panels Installed in the Same
Joist Space
If access is from above, completely install the radiant ceiling heat-
ing system (including wiring and testing), insulate above the panel
sets and then completely install the floor heating system.
If access is from below, completely install the floor heating system
(including wiring and testing), insulate below the heaters and then
completely install the ceiling heating system.
Repeat for each heating panel set, then continue to the next sec-
tion, Wire the Heating Panel Sets.
INSPECTION TESTING COMPLETION
10
Complementary Heating Products
Ceiling Heating Products RCH13P13W240V RCH17P17W240V RCH25P25W240V
Floor Warming Products 17 W/SF 17 W/SF 17W/SF
FLR13P8W120V 10 W/SF complementary complementary complementary
FLR13P8W240V 10 W/SF complementary complementary complementary
FLR17P10W120V 10 W/SF complementary complementary complementary
FLR17P10W240V 10 W/SF complementary complementary complementary
FLR25P17W120V 10 W/SF complementary complementary complementary
FLR25P17W240V 10 W/SF complementary complementary complementary
NOTE
INTENDED FOR INSTALLATION IN A COMMON JOIST SPACE WITH
COMPLEMENTARY CEILING HEATING PRODUCT RATED 17 WATTS
PER SQUARE FOOT MAXIMUM. See the Complementary Heating
Products table below for a list of heating elements that may be
used tin the same joist space.
Use at least 3 inches
/ 75 mm of unfaced
fiberglass insulation
to insulate between
the heating panel
sets of the two sys-
tems. If joists are
greater than 6 inches
/ 150 mm in depth
thicker insulation
must be used to
avoid air pockets
above the ceiling
heating panel sets.
See the Calorique
Ceiling Heating
System installation
manual for complete
details on the instal-
lation and testing of
that system.
CM1004 FLOOR - 2003-09-16.qxd 9/17/2003 2:59 PM Page 12