Specification
KICKSPACE HEATER SERIES
ENVIRONMENTAL PRODUCTS
1875 Dewey Avenue, Benton Harbor, MI 49023 • (269) 925-8818
MODEL KSWK
Recessed Wall Kit
KSWK-KS2004/KS2006/KS2008
BTU/Hr Outputs
Application
The KSWK QUIET-ONE 2000 recessed wall kit continues the tradi-
tion of supplying flexible solutions for those hard to heat areas.
Designed to fit between 16" O.C. studs, the KSWK can mount in any
wall of the house. It can also be used in ceiling applications, or be
installed in the end of counter cabinets or bathroom vanities. It can be
used in dressing rooms, walk-in closets or in mudrooms and entry
ways.
The cover is painted with a high grade primer finish which may be
used as is or can be painted, wall papered or marbleized.
Engineering Specifications
Construction. The one piece KS chassis and grille is manufactured
from high grade zinc coated steel. The grille is 3
1
⁄6" wider and 3
1
⁄2"
longer than the chassis in order to cover the wall opening while allow-
ing room to sweat the S & R copper.
Heat Exchanger. A highly efficient, headered coil, made of copper
tubes expanded into smooth aluminum plate fins (10 FPI), tested at 300
PSI, and sealed for quality. The heat exchanger is positioned in the
kickspace for maximum heat transfer over the coil.
Fan and Motor Assembly. High spec tangential SEL fan and motor
assembly consists of high static fan wheel and scroll, detachable
motor, replaceable “easy glide” sleeve bearings, and the fan and
motor cut out are protected to UL/CSA specifications. This fan and the
motor assembly is designed to enhance the “coanda” effect, and to
run whisper quiet without vibration.
Controls. The KS units have integral two speed, max.-off-min., fan
switches (optional wall mounted fan speed controller is available).
The LTC – low limit aquastat is also a high spec item with a close tol-
erance designed to close on a rise to 130 F+/-3 F and open at 110 F+/-
3 F. For low temperature systems you will have to change out the
aquastat located in the main electrical box easily removed from its
hold on clip.
Water Connections. Supply and return connections are
1
⁄2" sweat
connections located to the right of the unit as you face the grille. A
water vent with wide convenient screwdriver slot is accessible
through the grille.
Electrical Connections. 120/60/1 power supply is required. All that’s
required is to knock out the junction box hole you want to use and
wire to the L1 and L2 leads. There is a convenient one screw access
plate on the top of the unit to get at the ground.
Design
The KSWK QUIET-ONE 2000 recessed wall kit has been designed to
accept either a QUIET-ONE 2000 KS2004, KS2006, or KS2008 kickspace
heater. Units must be purchased separately.
• All capacities are rated upon actual installation outputs.
• For low speed ratings use: .85 for the KS2004, .75 for the
KS2006, .70 for the KS2008, and .65 for the KS2010.
• Heat throw: KS2004 = 10 ft. @ 50 CFM; KS2006 = 10 ft. @
75 CFM; KS2008 = 10 ft. @ 90 CFM; KS2010 = 10 ft. @ 125
CFM.
• When kickspace units are installed in a recessed wall kit,
BTUH out puts may be reduced by up to 10%.
SUBMITTAL DATA INFORMATION
KSWK 2010 Recessed Wall Kit