Installation manual
Command Manual - Port
Quidway S3000-EI Series Ethernet Switches Chapter 1 Ethernet Port Configuration Commands
Huawei Technologies Proprietary
1-10
Parameter
interval: Specifies time interval, ranging from 5 to 300 in seconds. The step is 5. The
default value is 300.
Description
Using the flow-interval command, you can configure a time interval. When calculating
port statistics information, the switch calculates the average port speed during the time
interval. Using the undo flow-interval command, you can restore the default value.
For the related command, see display interface.
Example
# Configure the time interval to 100 seconds on Ethernet0/1.
[Quidway-Ethernet0/1] flow-interval 100
1.1.11 interface
Syntax
interface { interface_type interface_num | interface_name }
View
System view
Parameter
interface_type: Specifies the port type. It can be Ethernet, or GigabitEthernet.
interface_num: Port number. It adopts slot number/port number format. For
S3026C/S3026C-PWR, the slot number ranges from 0 to 2. Slot 0 contains the fixed
Ethernet ports provided by the switch and the port number ranges from 1 to 24. Slot 1
or 2 contains the extended Ethernet ports provided by the two extended modules on
front panel and the port number can be 1 only. For S3026G and S3026T switches, the
slot number ranges from 0 to 2. Slot 0 contains the fixed Ethernet ports provided by
the switch and the port number ranges from 1 to 24. Slot 1 or 2 contains the two uplink
Ethernet ports provided by the switch and the port number can be 1 only.
For S3026E FM and S3026E FS Ethernet Switches, the slot number ranges from 0 to
4. Slot 0 contains the fixed Ethernet ports provided by the switch and the port number
ranges from 1 to 12. Slot 1 or 2 contains the extended Ethernet ports provided by the
two extended modules in the front panel and the port number ranges from 1 to 6. Slot
3 or 4 represents the extended Ethernet ports provided by the two extended modules
on the rear panel and the port number can only be 1.
interface_name: Specifies the port name in the interface_name= interface_type
interface_num format.