Installation manual
Command Manual - Security
Quidway S3000-EI Series Ethernet Switches
Chapter 2 AAA & RADIUS Protocol Configuration
Commands
Huawei Technologies Proprietary
2-41
Example
# Set the response timeout timer of RADIUS scheme, huawei, to 5 seconds.
[Quidway-radius-huawei] timer 5
2.2.26 timer quiet
Syntax
timer quiet minutes
undo timer quiet
View
RADIUS scheme view
Parameter
minutes: Quiet time interval, ranging from 1 to 255, in minutes. The default value is 5.
Description
Use the timer quiet command to set the quiet time interval after which the primary and
secondary RADIUS servers switch over.
Use the undo timer quiet command to set the quiet time interval to its default value.
The functions of the quiet time interval are as follows:
z The switch sends RADIUS packets to the primary RADIUS server.
z If the switch affirms that the primary server does not respond, it then sends
RADIUS packets to the secondary RADIUS server.
z After each quiet time interval, the switch sets the status of the primary RADIUS
server to active, and sends RADIUS packets to it next time.
Example
# Set the quiet time interval of the RADIUS scheme “RAserver” to 3 minutes.
[Quidway] radius scheme RAserver
[Quidway-radius-RAserver] timer quiet 3
2.2.27 timer realtime-accounting
Syntax
timer realtime-accounting minutes
undo timer realtime-accounting
View
RADIUS scheme view