Using stopbits command, you can configure the stop bits on the AUX (Console) port.
Using undo stopbits command, you can restore the default stop bits.
This command can only be performed in AUX user interface view.
By default, the value is 1.
Example
# Configure 2 stop bits on the AUX (Console) port.
[Quidway-ui-aux0] stopbits 2
1.1.26 super
Syntax
super [ level ]
View
User view
Parameter
level: User level, ranging 0 to 3. The default value is 3.
Description
Using super command, you can enable the user to change to user level from the
current user level. If the user has set the super password [ level level ] { simple |
cipher } password, then user password of the higher level is needed, or the former user
level will not change.
Login users are classified into four levels that correspond to the four command levels
respectively. After users of different levels log in, they can only use commands at the
levels that are equal to or lower than its own level.
For the related commands, see super password, quit.
Example
# change to user level 3 from the current user level.
<Quidway> super 3
Password:
1.1.27 super password
Syntax
super password [ level level ] { simple | cipher } password
undo super password [ level level ]